Installation of chemical anchors
Please respect the following procedure for chemical anchors installation. No
mechanical anchors allowed. Chemical anchors used in IRT 710 is HILTI M16x125
anchors.
Note
Action
xx1700001665
Drill the hole with rotary hammer and set the depth
gauge to the correct drilling depth.
Diamond coring: Mark the correct drilling depth
on the height adjustment mechanism.
1
xx1700001666
xx1700001667
Clean the hole immediately before setting the
anchor. Remove drilling dust and standing water
from the base of the hole by blowing out well with
at least 4 strokes of the blow-out pump, or using
compressed air or an industrial vacuum cleaner.
The anchor holes must be free of dust, water, ice,
oil, bitumen, chemicals or any other foreign matter
or contaminants. Poorly-cleaned holes leads to
poor hold.
2
xx1700001668
Ensure that the specified setting depth is marked
on the anchor rod. If not, add an embedment
mark, for example with tape or marker.
3
Continues on next page
130
Product manual - IRT 710
3HKA00000186299-001 Revision: B
© Copyright 2023 ABB. All rights reserved.
3 Installation and commissioning
3.4.7.2 Recommendations for floor mounting
Continued
Summary of Contents for IRT 710
Page 1: ...ROBOTICS Product manual IRT 710 ...
Page 14: ...This page is intentionally left blank ...
Page 58: ...This page is intentionally left blank ...
Page 84: ...This page is intentionally left blank ...
Page 360: ...This page is intentionally left blank ...
Page 364: ...This page is intentionally left blank ...
Page 378: ...This page is intentionally left blank ...
Page 380: ...This page is intentionally left blank ...
Page 383: ......