Note
Action
xx1800001982
Pull-up the black rubber seal. Fill-in the Memol-
ub
®
with a manual grease pump. This manual
operation is required only if the Memolub has
been used without a cartridge, if the previous
cartridge has run out of grease. Place the pump
nipple at the entry of the Memolub, and pump
until you see grease coming out at the outlet. Two
strokes of the manual pump are usually enough.
2
xx1800001983
Pull-up the black strap to reveal the battery case.
Insert a new Memolub battery: hold it by the black
plastic strap & insert it in the Memolub respecting
the instructions on the label. If the battery is cor-
rectly inserted the motor is activated during 1 sec.
to check that the motor is working properly. Put
the black rubber seal back in place.
3
xx1800001984
Remove the paper disc from the replacement
cartridge. Fill-in the required dates: "Started" and
"Replace before". The "replace before" date is
depending on the Memolub program. Put the pa-
per disc back in place in order to see the instruc-
tions when the Memolub is closed.
4
xx1800001985
Press softly on the cartridge until the grease
comes out, to avoid injecting air into the pump.
5
xx1800001986
Place the cartridge at the inlet of the pump. Check
that the cartridge is correctly inserted in the inlet
of the pump.
6
Continues on next page
212
Product manual - IRT 710
3HKA00000186299-001 Revision: B
© Copyright 2023 ABB. All rights reserved.
4 Maintenance
4.5.2 Automatic lubrication system
Continued
Summary of Contents for IRT 710
Page 1: ...ROBOTICS Product manual IRT 710 ...
Page 14: ...This page is intentionally left blank ...
Page 58: ...This page is intentionally left blank ...
Page 84: ...This page is intentionally left blank ...
Page 360: ...This page is intentionally left blank ...
Page 364: ...This page is intentionally left blank ...
Page 378: ...This page is intentionally left blank ...
Page 380: ...This page is intentionally left blank ...
Page 383: ......