Removal
xx1000000238
Auxiliary contact
1
Information
Action
DANGER
Before any work inside the cabinet, read the safety
information in section
1
xx1000000212
Turn the main power switch to
OFF
.
2
Remove the cable harness from the auxiliary con-
tact.
3
Push the auxiliary contact towards the center of the
contactor.
4
Remove the auxiliary contact.
5
Continues on next page
Product manual - IRBP /D2009
245
3HAC037731-001 Revision: T
© Copyright 2010-2020 ABB. All rights reserved.
6 Repair
6.8.4 Replacing auxiliary contact
Continued