Note
Action
Remove and clean the pipe after the oil is
drained.
Note
There will be some oil left in the gearbox
after draining.
8
Tightening torque: 10 Nm
Refit oil plugs.
9
Removing the process hub screws
Note
Action
DANGER
Make sure that all supplies for electrical power,
hydraulic pressure, and air pressure are turned
off.
1
For robots with protection class
IP30
Remove the screws locking the process hub.
2
xx2300000487
Push the process hub to the outer arm.
3
Removing the cover of the outer arm
Note
Action
DANGER
Make sure that all supplies for electrical power,
hydraulic pressure, and air pressure are turned
off.
1
Continues on next page
Product manual - IRB 930
387
3HAC086009-001 Revision: A
© Copyright 2023 ABB. All rights reserved.
5 Repair
5.6.8 Replacing the outer arm
Continued