Note
Action
xx2300000486
Jog all axes to zero position.
2
DANGER
Turn off all:
•
electric power supply
•
hydraulic pressure supply
•
air pressure supply
to the robot, before entering the safeguarded
space.
3
Removing the SMB cover
Note
Action
DANGER
Make sure that all supplies for electrical power,
hydraulic pressure, and air pressure are turned
off.
1
ELECTROSTATIC DISCHARGE (ESD)
The unit is sensitive to ESD. Before handling the
unit read the safety information in section
unit is sensitive to ESD on page 46
2
For robots with protection class
IP30 (option 3350-300)
Remove the screws on the SMB cover to the base.
3
Pull the SMB cover with the SMB unit assembly
out together.
4
xx2300000489
Continues on next page
Product manual - IRB 930
131
3HAC086009-001 Revision: A
© Copyright 2023 ABB. All rights reserved.
5 Repair
5.3.2 Replacing the SMB unit and battery unit
Continued