Parameter Navigation and Groups 8-3
MN448
Figure 8-2 Parameter Group Structure and Description
“Status Mode”
>1s Parameter
Group Mode
Press Enter on 0000 in the Par L
Group to access Read Only
Status Parameter
Press to enter to access group
parameter edit mode
Use the Le
ft
/Right Arrows
to select group
Up/Down
Arrows Scroll
Between
Parameters
2017
2105
Max Current Limit
DC Injection Speed
0102
0104
0107
0109
0110
0111
0115
0120
0121
0140
Rotor Speed
Motor Current
Applied Motor Volts
Heatsink Temp
Speed Ref. IN
Kwh/MWh Meter
Analog IN 1
Analog IN 2
Hours Run Meter
DC Bus Voltage
0150
0160
0183
0188
0189
0190
0192
0193
0194
0402
Internal Drive Temp
Digital IN Status
OP Time >85C
OP Time >80C
Drive Fan OP Time
DC BUS Ripple Log
Heatsink Temp Log
Ambient Temp Log
Run Time Last Trip 1
DC BUS Ripple
0406
DC BUS V Log
9902
9905
9906
9907
0401
1103
1202
1203
1204
Digital IN Function
Motor BEMF Volts
Motor Rated Freq
Trip History Log
Command Source
Preset / Jog Speed 1
Preset / Jog Speed 2
Preset / Jog Speed 3
Motor Rated Current
1301
2008
2102
Analog IN 1 Offset
Max Speed Limit
Stop Mode
2202
2203
Accel Ramp Time
Decel Ramp Time
0415
0416
3301
3303
Run Time Last Trip 2
Drive Switching Freq
Software ID
Drive Serial No.
3304
Drive ID
2106
2301
DC Injection Current
Vector Mode Gain
2605
9903
Operating Mode Sel
Motor Control Mode
9910
11201
Motor Autotune
Motor Stator Rs
11203
11206
Motor Stator Lsd
Motor Stator Lsq
0000
0401
1100
1103
1202
1203
1204
1205
1300
1301
Read Only Param
Trip History Log
Command Source
Preset / Jog Speed 1
Preset / Jog Speed 2
Preset / Jog Speed 3
Preset / Jog Speed 4
Analog IN 1 Format
Analog IN 1 Offset
Keypad Mode
1302
1304
1401
1501
1602
1603
2007
2008
2020
2101
Analog IN 1 Scaling
Analog IN 2 Format
Analog Out Function
Access Lock
Access Code
Min Speed Limit
Max Speed Limit
Brake Enable
Flying Start
Relay Out Function
2102
Stop Mode
2104
2108
2202
2203
DC Injection Time
Terminal Restart
Accel Ramp Time
Decel Ramp Time
2206
Decel Ramp Time 2
2500
2501
2601
2603
2606
2610
2611
3005
3200
3400
Skip Freq Band
Skip Frequency
V/F Mode Boost
Switching Freq
V/F Adjust Voltage
V/F Adjust Freq
Thermal Overload
Relay Level
Display Scaling
Energy Optimizer
4001
4002
4005
4010
4011
4016
5302
9902
9905
9906
PI Proportional Gain
PI Integral Gain
PI Ref Source
PI Digital Ref
PI Feedback Select
Serial Comm Config
Digital IN Function
Motor BEMF Volts
Motor Rated Current
PI Operating Mode
9907
Motor Rated Freq
9908
Motor Rated Speed
Summary of Contents for EC Titanium ECS100A1H1DF4
Page 1: ... MN448_May 2020 May 2020 EC Titanium Manual User s guide ...
Page 10: ...1 4 Introduction MN448 ...
Page 20: ...3 4 Mechanical Information and Mounting MN448 ...
Page 26: ...4 6 Electrical Installation and Planning MN448 ...
Page 32: ...5 6 Control Pad Wiring and Keypad Interface MN448 ...
Page 36: ...6 4 Keypad Programming and Basic Operation MN448 ...
Page 44: ...8 4 Parameter Navigation and Groups MN448 ...
Page 51: ...9 7 Control Modes MN448 ...
Page 77: ...11 8 Standalone Motor and ABB Drive Setup MN448 ...
Page 99: ...A 12 Modbus RTU Example Connection MN448 ...
Page 102: ......