Introduction 1-1
MN448
Chapter 1
Introduction
The EC Titanium Series of Motors & Integrated Motor Drives (IMDs) are highly efficient, non-rare earth motors with Ferrite
Assisted Synchronous Reluctance rotors. The IMD Versions provide an integrated drive which simplifies installation
and wiring, reduces cost, and saves valuable panel space. Focused on Variable Torque / Pump, Fan, and Compressor
Applications.
This manual is intended to provide information needed for planning the installation, start-up, operating and servicing the
IMD. It includes information on:
- Safety Instructions
- Installation and Wiring of the IMD
- Programming the IMD
The reader is expected to know the fundamentals of electricity, wiring, electrical components and electrical schematic
symbols.
abb.com can be accessed for a full list of support materials such as literature, firmware, IMD specific parameter sets, and
programming software.
1.1 Getting Assistance from ABB
For technical assistance, contact your local ABB representative. Contact phone numbers are located on the inside back
cover of this guide. Before calling, review the troubleshooting section later in this manual. You will be asked for the IMD
model number or catalog number that is located on the nameplate.
1.2 Safety Notices
This chapter contains the safety instructions which you must follow when installing, operating and servicing the drive.
If ignored, physical injury or death may follow, or damage may occur to the IMD or driven equipment. Read the safety
instructions before you work on the unit.
USE of WARNINGS:
Warnings caution you about conditions which can result in serious injury or death and/or damage to the equipment and
advise on how to avoid the danger. The following warning symbols are used in this manual:
Electricity warning warns of hazards from electricity which can cause physical injury and/or
damage to the equipment.
General warning warns about conditions, other than those caused by electricity, which can result
in physical injury and/or damage to the equipment.
1.2.1 Safety in Installation and Maintenance
Electrical Safety -
These warnings are intended for all who work on the drive, motor cable or motor.
WARNING:
Ignoring the following instructions can cause physical injury or death, or damage to the equipment:
• Only qualified electricians are allowed to install and maintain the IMD.
• Never work on the IMD or power cable when input power is applied. After disconnecting the input power, always wait for
10 minutes to let the intermediate circuit capacitors discharge before you start working on the IMD or power cable.
Always ensure by measuring with a multimeter (impedance at least 1 Mohm) that:
1. There is no voltage between the drive input phases L1, L2 and L3 and the ground.
2. There is no voltage between terminals U, V, W (and + and BR if supplied on the IMD) and the ground.
• voltage between drive input phases L1, L2 and L3 and the frame is close to 0V.
• voltage between terminals (+ and BR if supplied on the IMD) and the frame is close to 0V.
• Do not work on the control cables when power is applied to the IMD or to the external control circuits. Externally supplied
control circuits may carry dangerous voltage even when the input power of the drive is switched off.
• Do not make any insulation or voltage withstand tests on the drive.
Summary of Contents for EC Titanium ECS100A1H1DF4
Page 1: ... MN448_May 2020 May 2020 EC Titanium Manual User s guide ...
Page 10: ...1 4 Introduction MN448 ...
Page 20: ...3 4 Mechanical Information and Mounting MN448 ...
Page 26: ...4 6 Electrical Installation and Planning MN448 ...
Page 32: ...5 6 Control Pad Wiring and Keypad Interface MN448 ...
Page 36: ...6 4 Keypad Programming and Basic Operation MN448 ...
Page 44: ...8 4 Parameter Navigation and Groups MN448 ...
Page 51: ...9 7 Control Modes MN448 ...
Page 77: ...11 8 Standalone Motor and ABB Drive Setup MN448 ...
Page 99: ...A 12 Modbus RTU Example Connection MN448 ...
Page 102: ......