7.2 Quick Start Motor Parameter Data
If a factory reset has been performed, the motor data will need to be re-entered into the appropriate parameters. Motor
Data is available on the Motor Nameplate, see Figure 2.2 for detailed information. For detailed information on parameter
navigation see Chapter 8 Parameter Navigation.
Press and hold the
navigate key for >1 second to enter parameter view mode and enter motor data from the motor
nameplate into the parameters in Table 7-1. Enter the rated RPM (nameplate) of the motor in 9908 MOTOR RATED SPEED to
allow the display of the estimated motor speed.
Table 7-1 Factory Motor Setup Parameters
Description
Parameter Number
Factory Settings
BEMF (Back EMF) Voltage
9905
Set to Motor
Nameplate Values
(see section 2.2)
Motor Rated Amps
9906
Motor Rated Frequency
9907
Motor Stator Resistance (Rs)
11201
Ld (mH) Motor Inductance (Lsd)
11203
Lq (mH) Motor q-axis Inductance (Lsq)
11206
Minimum Speed
2007
15 HZ
Maximum Speed
2008
Motor Max Speed
Stop Mode
2102
1 = Coast to Rest
Control Mode
9903
2 = PM Control
7.3 Customizing Your Application
Factory settings may give satisfactory performance; however certain adjustments may be beneficial.
Parameter Name
Parameter
Adjustment
Minimum Frequency Limit
2007
Minimum output frequency
Maximum Frequency Limit
2008
Maximum output frequency
Primary Command Source
1103
Selects the reference input for the drive.
Digital Input Function Select
9902
Defines the function of the digital inputs
Stop Mode
2102
Select method of stopping required when drive is
disabled.
Acceleration Ramp
2202
Adjust as need for your application. Short
Acceleration or Deceleration times may cause excess
motor current and may result in it tripping or the
motor stalling.
Deceleration Ramp
2203
Analog Input Format
1300
Set as required by the application (0-10V, 10-0V,
4-20mA)
Voltage Boost
2603
Any hard to start load will benefit from voltage boost.
Permits a boost of up to 25% of full motor voltage to
be applied.
NOTE: The Analog Input Value scales with the maximum output frequency setting in 2008.
Example: 0-10V Input motor will run 1800 RPM at a 10VDC reference when 2008 = 60 HZ.
Summary of Contents for EC Titanium ECS100A1H1DF4
Page 1: ... MN448_May 2020 May 2020 EC Titanium Manual User s guide ...
Page 10: ...1 4 Introduction MN448 ...
Page 20: ...3 4 Mechanical Information and Mounting MN448 ...
Page 26: ...4 6 Electrical Installation and Planning MN448 ...
Page 32: ...5 6 Control Pad Wiring and Keypad Interface MN448 ...
Page 36: ...6 4 Keypad Programming and Basic Operation MN448 ...
Page 44: ...8 4 Parameter Navigation and Groups MN448 ...
Page 51: ...9 7 Control Modes MN448 ...
Page 77: ...11 8 Standalone Motor and ABB Drive Setup MN448 ...
Page 99: ...A 12 Modbus RTU Example Connection MN448 ...
Page 102: ......