6.6.7 Damping
The damping can be set within the range from 1s to a maximum of 100 s. It represents the time required for
the converter to reach the value of 99 % of a step change.
6.6.8 Low
Flow
Cutoff
The value set is the low flow cutoff limit in percent of the QmMax setting. The maximum low flow cutoff setting
is 10 %. The switching hysteresis is 0.1 %. If a value of 0 % is entered for the low flow cutoff, then the switch-
ing hysteresis is also turned off.
6.6.9 System
Zero
After pressing „ENTER“ the selection of whether a manual or automatic zero adjustment is to conducted can
be made using „DATA“ or „STEP“.
„System Zero Manual“ allows the direct entry of a zero value for the system zero. This could be used in order
to change the system zero value determined by the automatic adjustment. Before selecting the automatic
zero adjustment function assure that the operating requirements below are satisfied (“Installation Require-
ments/System Sizing Information” on Page 15):
•
no flowrate
•
no vibration
•
no pressure shocks
•
no gas bubbles in fluid
•
operating conditions (e.g. operating temperature and operating pressure)
Damping
5.0 s
Low Flow Cutoff
2.1 %
System Zero adj.
-0.0111 %
System Zero adj.
manual?
System Zero adj.
automatic?
6 Converter
Summary of Contents for CoriolisMaster FCM2000
Page 6: ...Contents 6 FCM2000 D184B111U02...
Page 91: ...11 Certificates D184B111U02 FCM2000 91 Fig 43...
Page 92: ...11 Certificates 92 FCM2000 D184B111U02 11 2 EU Type Examination Certificate Fig 44...
Page 93: ...11 Certificates D184B111U02 FCM2000 93 Fig 45...
Page 94: ...11 Certificates 94 FCM2000 D184B111U02 Fig 46...
Page 95: ...11 Certificates D184B111U02 FCM2000 95 Fig 47...
Page 96: ...11 Certificates 96 FCM2000 D184B111U02 Fig 48...
Page 97: ...11 Certificates D184B111U02 FCM2000 97 Fig 49...
Page 98: ...11 Certificates 98 FCM2000 D184B111U02 Fig 50...
Page 99: ...11 Certificates D184B111U02 FCM2000 99 Fig 51...
Page 100: ...11 Certificates 100 FCM2000 D184B111U02 11 3 PED Certificate of Compliance Fig 52...
Page 101: ...11 Certificates D184B111U02 FCM2000 101 11 4 EHEDG Certificate Fig 53...
Page 103: ......