Introduction to the manual 21
Incoming cubicle
(ICU)
Cubicle with input power terminals, main switching and disconnecting devices, etc.
See
.
Inverter
Converts direct current and voltage to alternating current and voltage.
Inverter module
Inverter bridge, related components and converter DC link capacitors enclosed
inside a metal frame or enclosure. Intended for cabinet installation.
Inverter module
cubicle
Cubicle which includes inverter module(s). See
.
Inverter unit (INU)
Rotor-side converter unit. Consists of the converter module and the related
accessories (such as fuses, switches, control unit, etc.) See
Intermediate circuit
See
.
LCU
Liquid cooling unit
LCL
Grid-side filter that suppresses voltage distortion and current harmonics. Essential
part of the grid-side converter.
Main circuit breaker
(MCB)
Electrically-controlled main switching and protecting device. Also used as the main
disconnector.
NAMU
Auxiliary Measuring Unit. Performs voltage measurement for IGBT supply unit
RMIO board.
NCAN
CANopen® Adapter Module
NDCU
Drive Control Unit. Consists of a AMC board and NIOC board built into a metal
housing. NDCU unit controls the rotor-side converter.
NDNA
DeviceNet™ Adapter Module
NETA
Ethernet Adapter Module
NIBA
Interbus-S® Adapter Module
NIOC
Input/Output Board. Part of the NDCU Drive Control unit
NPBA
PROFIBUS DP® Adapter Module
NTAC
Pulse Encoder Interface Module
NUIM
Voltage and Current Measurement Unit. Performs voltage and current
measurement for AMC board.
PPCS
Power Plate Communication System. Communication protocol used with optic fiber
link which controls the power stage of the converter modules.
RAIO
Analog I/O Extension Module
RDCO
DDCS Communication Option with optic fiber channels
RDCU
Drive Control Unit which contains an RMIO (Motor Control and I/O) board. An
RDCU unit controls the grid-side converter.
RFI
Radio Frequency Interference
RMIO
Motor Control and I/O Board. Part of the RDCU Drive Control Unit
Rotor-side converter
A converter that is connected to the generator rotor and controls its operation. The
rotor-side converter is also called the inverter unit or INU.
UPS
Uninterruptible power supply
Term/Abbreviation
Explanation
Summary of Contents for ACS800-67LC
Page 1: ... ABB WIND TURBINE CONVERTERS ACS800 67LC wind turbine converters Hardware manual ...
Page 4: ......
Page 16: ...16 Safety instructions ...
Page 22: ...22 Introduction to the manual ...
Page 42: ...42 Operation principle and hardware description ...
Page 52: ...52 Mechanical installation ...
Page 79: ...Electrical installation 79 3 3 Rotor side cable connection terminals U2 V2 W2 ...
Page 92: ...92 Maintenance 4 6 5 5 ...
Page 103: ...Maintenance 103 Bussmann fuses Mersen fuses ...
Page 109: ...Maintenance 109 5 6 7 ...
Page 131: ...Technical data 131 Declaration of incorporation ...
Page 136: ...136 Dimension drawings ACS800 67LC 1075 0575 7 and 1375 0575 7 ...
Page 137: ...Dimension drawings 137 With 400 mm wide incoming cubicle option C111 ...
Page 138: ...138 Dimension drawings ACS800 67LC 1375 1125 7 ...
Page 139: ...Dimension drawings 139 With 400 mm wide incoming cubicle option C111 ...
Page 140: ...140 Dimension drawings ACS800 67LC 1595 0865 7 and 2035 1125 7 ...
Page 141: ...Dimension drawings 141 With 400 mm wide incoming cubicle option C111 ...
Page 143: ...Dimension drawings 143 Options 2H370 and C111 Option 1H371 ...
Page 144: ...144 Dimension drawings Options 1H371 and C111 Options 2H371 and C111 ...
Page 145: ...Dimension drawings 145 Option H378 Options H378 and C111 ...
Page 147: ...Dimension drawings 147 Option 2H372 ...
Page 148: ...148 Dimension drawings Option 3H372 ...
Page 149: ...Dimension drawings 149 Option 1H373 ...
Page 150: ...150 Dimension drawings Option 2H373 ...
Page 151: ...Dimension drawings 151 Option 3H373 ...