Installation checklist 87
7
Installation checklist
Check the mechanical and electrical installation of the converter before start-up. Go
through the checklist below together with another person.
WARNING!
Read and follow the instructions given in
.
Ignoring the instructions can cause physical injury or death, or damage to
the equipment.
Open the load switch disconnector of the converter and lock it to open position. Ensure by
measuring that the converter is not powered.
Mechanical installation
Electrical installation
See chapters
Planning the electrical installation, Electrical installation.
The converter has been fixed properly to floor, and if necessary (due to vibration etc.), also from top
to the wall or roof.
The ambient operating conditions are within the allowed limits. See chapter
If the lifting bars have been removed, ensure that the bolts are re-fastened to retain the cabinet
degree of protection.
The converter is grounded properly and there is an adequately sized protective ground conductor
between the converter and the power supply network (transformer).
All protective ground conductors have been connected to the appropriate terminals and the terminals
have been tightened (pull conductors to check).
Summary of Contents for ACS800-67LC
Page 1: ... ABB WIND TURBINE CONVERTERS ACS800 67LC wind turbine converters Hardware manual ...
Page 4: ......
Page 16: ...16 Safety instructions ...
Page 22: ...22 Introduction to the manual ...
Page 42: ...42 Operation principle and hardware description ...
Page 52: ...52 Mechanical installation ...
Page 79: ...Electrical installation 79 3 3 Rotor side cable connection terminals U2 V2 W2 ...
Page 92: ...92 Maintenance 4 6 5 5 ...
Page 103: ...Maintenance 103 Bussmann fuses Mersen fuses ...
Page 109: ...Maintenance 109 5 6 7 ...
Page 131: ...Technical data 131 Declaration of incorporation ...
Page 136: ...136 Dimension drawings ACS800 67LC 1075 0575 7 and 1375 0575 7 ...
Page 137: ...Dimension drawings 137 With 400 mm wide incoming cubicle option C111 ...
Page 138: ...138 Dimension drawings ACS800 67LC 1375 1125 7 ...
Page 139: ...Dimension drawings 139 With 400 mm wide incoming cubicle option C111 ...
Page 140: ...140 Dimension drawings ACS800 67LC 1595 0865 7 and 2035 1125 7 ...
Page 141: ...Dimension drawings 141 With 400 mm wide incoming cubicle option C111 ...
Page 143: ...Dimension drawings 143 Options 2H370 and C111 Option 1H371 ...
Page 144: ...144 Dimension drawings Options 1H371 and C111 Options 2H371 and C111 ...
Page 145: ...Dimension drawings 145 Option H378 Options H378 and C111 ...
Page 147: ...Dimension drawings 147 Option 2H372 ...
Page 148: ...148 Dimension drawings Option 3H372 ...
Page 149: ...Dimension drawings 149 Option 1H373 ...
Page 150: ...150 Dimension drawings Option 2H373 ...
Page 151: ...Dimension drawings 151 Option 3H373 ...