Parameters 63
Read Only Status parameters
The user must be in the
Long Parameter group
to gain access to the Read only
status parameters.
In the Long Parameter Group when the user scrolls to parameter “
0000
”
, pressing
will display “
0104
”, t
he User can then scroll to the required Read only status
parameter (as listed in the table above). Pressing
once more will then display the
value of that particular Read only status parameter.
For those parameters which have multiple values (e.g. software ID parameter
3301
),
pressing the and keys will display the different values within that parameter.
Pressing
returns to the next level up. If
is then pressed again (without
pressing or ), the display changes to the next level up (main parameter level,
i.e. Parameter
“
0000
”).
The following table includes the descriptions of all Read Only status parameters.
Actual signals
No.
Name/Value
Description
01 OPERATING DATA
Basic signals for monitoring the drive (read-only).
For selection of an actual signal to be displayed on the control panel,
see parameter
3405
DISPLAY SCALING SOURCE.
0102
Rotor Speed
(Estimated)
In vector control mode, this parameter displays the estimated rotor
speed of the motor.
0104
Motor Current
8 most recent values prior to trip, updated every 250ms
0107
DC BUS VOLTAGE
Displays the instantaneous DC Bus Voltage internally within the drive
in V DC. (0…1000V dc)
0109
APPLIED MOTOR
VOLTAGE
Displays the instantaneous output voltage from the drive to the motor
V AC. (0…600V AC)
0110
INTERNAL
HEATSINK
TEMPERATURE
Temperature of heatsink in
°
C (-20 … 100 °C)
0111 SPEED
REFERENCE
INPUT
Displayed in Hz if Parameter
9908
MOTOR RATED SPEED = 0,
otherwise displayed in RPM. (-
2008
…
2008)
0115
KWh/MWh METER
Total number of KWh/MWh consumed by the drive.
0120
ANALOG INPUT 1
APPLIED SIGNAL
LEVEL
Displays the signal level applied to analog input 1 (Terminal 6) in %
after scaling and offsets have been applied.
0121
ANALOG INPUT 2
APPLIED SIGNAL
LEVEL
Displays the signal level applied to analog input 2 (Terminal 4) in %
after scaling and offsets have been applied.
0126
PI CONTROLLER
OUTPUT
Displays the output level of the PI controller in %.
0140
HOURS RUN METER
Not affected by resetting factory default parameters.
(0 to 99 999 hours)
0150
INTERNAL DRIVE
TEMPERATURE
Actual internal ambient temperature in °C
ACS260-04.book Page 63 Thursday, December 24, 2020 4:33 PM
Summary of Contents for ACS260-04 Series
Page 2: ...ACS260 04 book Page 2 Thursday December 24 2020 4 33 PM ...
Page 4: ...ACS260 04 book Page 4 Thursday December 24 2020 4 33 PM ...
Page 8: ...8 Table of contents ACS260 04 book Page 8 Thursday December 24 2020 4 33 PM ...
Page 14: ...14 Safety ACS260 04 book Page 14 Thursday December 24 2020 4 33 PM ...
Page 22: ...22 Mechanical installation ACS260 04 book Page 22 Thursday December 24 2020 4 33 PM ...
Page 32: ...32 Electrical installation ACS260 04 book Page 32 Thursday December 24 2020 4 33 PM ...
Page 92: ...92 Technical Data ACS260 04 book Page 92 Thursday December 24 2020 4 33 PM ...
Page 96: ...96 Options and Kits ACS260 04 book Page 96 Thursday December 24 2020 4 33 PM ...