AD-4405A Weighing Indicator
Page 41
10.1.2. Setting the Upper/Lower Limit Values
Step 1 By pressing the
SETPOINT
key, the selected code memory number is displayed
and the first comparison class term (ex. Hi, TG etc.) is blinking.
Step 2 Select the comparison class using the following keys:
SETPOINT
key ........The key to select a comparison class.
ESC
key..................The key to return to the previous stage (weighing mode or
code memory number selection mode).
ENTER
key .............The key to proceed to step 3.
Step 3 Set the setpoint values using the following keys:
0
-
9
key .................The key to enter a value.
ESC
key..................The key to return to step 2 without changing the set value.
ENTER
key .............The key to store the value and return to step 2.
Setting Order and Display for Weight Check Mode
f22
MODE
Display
1
2
3
4
5
1 Upper
Setpoint
Upper
Lower
Lower
1 Class
Hi
Lo
Comparator
HI
LO
2 Upper
Setpoint
Target
Upper
Lower
Lower
2 Class
TG
Hi
Lo
Comparator
OK
HI
LO
3 Upper
Setpoint
Target
Upper
Lower
Lower
3 Class
TG
Hi
Lo
Comparator
OK
HI
LO
Unit
%
%
4 5-stage
Setpoint
HiHi
Hi
Lo
LoLo
1
Class HH
Hi
Lo
LL
Comparator
HI
HI
LO
LO
Triangle
2
3
5 5-stage
Setpoint
Target HiHi
Hi
Lo LoLo
2
Class TG HH
Hi
Lo
LL
Comparator
OK
HI
HI
LO
LO
Triangle
2
3
6 5-stage
Setpoint
Target HiHi
Hi
Lo LoLo
3
Class TG HH
Hi
Lo
LL
Comparator
OK
HI
HI
LO
LO
Unit
%
%
%
%
Triangle
2
3
10.1. Weight Check Mode