Page
8
AD-4405A Weighing Indicator
4. Description of Panels and Symbols
4.1. Front Panel Description
N
o.
Name Description
1 STABLE
Indicates when the display is stable.
2 NET
Indicates when the display is the net weight.
3 ZERO
Indicates when the display weight is in the Zero range.
4 Annunciator
lndicates various weighing status or functional selection.
PT
Indicates when PRESET TARE value is being used.
READY
Indicates the state of comparison or batching.
M+
(Accumulation) Indicates when there is a result of addition or accumulation.
1,2,3
(Triangle ) Depending on the function selected, indicates various states.
5 MAIN display
Displays the weight, accumulated data or stored parameters.
6 UNIT part
Unit used to weigh.
7 HI/OK/LO
Indicates the result of comparison.
8 Capacity
label
To note the capacity and division. (provided as an accessory)
9 Key switches
To display, output and perform various settings
CODE key
The key to select the code memory.
SAMPLE key
The key to set the unit weight for the counting function.
SETPOINT key
The key to set the comparator value.
PT key
The key to set the PRESET TARE value.
TOTAL key
The key to display the total weight.
M+ key
The key to perform accumulation.
START key
The key to start comparison / batch weighing.
STOP key
The key to stop comparison / batch weighing.
FEED key
The key to feed the paper of the optional Printer.
MODE key
The key to switch units or setting parameters.
0 – 9 key
The key to input any numerical settings.
A – F key
Used to enter setting values (press NET/GROSS key at a time).
4. Description of Panels and Symbols
2
1
3
4
5
6
7
8
9
10