10.1.1. Condition Formula for Comparison
Comparison is performed based on the following formula.
Upper/lower comparison
Judge Condition
Formula Display
Output
HI
Upper limit (Hi limit) value < Displayed value
HI
HI
OK Lower
limit
value
Displayed value
Upper limit value
OK
OK
LO
Displayed value < Lower limit (Lo limit) value
LO
LO
5-stage comparison
Judge Condition
Formula Display
Output
HiHi
HiHi limit value < Displayed value
HI, 2
HI
HI
Upper limit (Hi limit) value < Displayed value
HI
HI, OK
OK Lower
limit
value
Displayed value
Upper limit value
OK
OK
LO
Displayed value < Lower limit (Lo limit) value
LO
LO, OK
LoLo
Displayed value < LoLo limit value
LO, 3
LO
The decimal point is ignored. Example: If the upper limit value is 10.0, enter 100.
These parameters are stored in non-volatile memory, and are not lost even if
power is turned off (except code 0 memory).
When the displayed value becomes an overload (positive over), HI (over) is output.
When the displayed value becomes an underload (negative over), LO (under) is
output.
This function compares the Hi / HiHi limit value first.
This function does not check the relationship between the upper and lower limit
values.