AD-4405A Weighing Indicator
Page
27
Data Output
Item
Parameter
Description
*
*
0
No data output
1
Analog output
Set
f31
,
32
,
33
2
Serial output
f30
Data output
3
Serial output (Zero suppressing)
RS-232C,
RS-422/485
*:
Initial settings.
Analog Output
Item
Parameter
Description
*
0
Displayed data
1
Gross data
f31
Output data
2
Net data
f32
Weight value at 4mA output
-999999
to
999999
(Initial setting is
0
)
f33
Weight value at 20mA output
-999999
to
999999
(Initial setting is
10000
)
Polarity is
changed by
pressing the +/-
key.
*:
Initial settings.
Serial Data Format
Item
Parameter
Description
x
0
Terminator
x
1
Device ID (selected at
f06
)
x
2
Code memory number
x
3
Data number *
x
4
Result of comparison
x
5
Date
x
6
Time
x
7
Accumulated
data
x
8
Accumulation
count
x
9
Stable / Over
x
a
Displayed
weight
x
b
Gross
weight
x
C
Net
weight
x
d
Tare
weight
x
e
Weight type (
G /N / T
, refer to
Cf06
)
f34
[Type3]
Serial data format 1
Initial value
19
,
2e
,
3a
4f
e50
f35
[Type3]
Serial data format 2
Initial value
17
2f
e30
x
f
Weight unit (Refer to
Cf07
)
Left 3 digits: order
of output (1-999),
select using the
ZERO
key
Right 1 digit:
output data,
select using the
0
-
9
,
A
-
F
keys
“
E
xxx” indicates
the end of data
to output
NET/GROSS
key:
Expand or
shorten output
data length
1 The comma of the parameter display indicates that the comma (
f46
=
0
, semi-colon
for
f46
=
1
) is output after the data. To turn this mark on and off, press the
9
key
while pressing
NET/GROSS
key.
Output of the initial setting of
f34
(19, 2E, 3A 4F E50) is like “ST,GR,
+
12345.6kg”.
2 The data number *(parameter 3) increments automatically with each serial data
output from 1 to 99999 (the next of 99999 is 1). The starting number can be set
using the keys.
6.2.
F-Functions