Page
32
AD-4405A Weighing Indicator
6.3. CF-Functions
Item
Parameter
Description
*
0
No limitation
Cf00
Zero tracking width, motion
detection condition
1
Use limitation at
f01
,
f02
,
f03
,
f27
and
f28
.
*
0
2% of CAP,
Tare limit is 100 % CAP
1
10% of CAP, Tare limit is 100 % CAP
2
3% of CAP,
Tare limit is 50 % CAP
Cf01
Zero range (by pressing
the ZERO key)
3
4% of CAP,
Tare limit is 50 % CAP
0
Not to zero when turning the display on.
*
1
10% of CAP
2
3% of CAP
Cf02
Power on zero range
(Reference: CAL 0)
3
4% of CAP
0
Gross when displaying gross.
1
Gross
Cf03
Zero tracking
*
2
Gross or Net when displaying net.
TARE, ZERO in motion / TARE at negative gross
*
0
Not accepted
/
Not accepted
1
Execute /
Not
accepted
2
Not accepted
/
Execute
Cf04
TARE, ZERO in motion /
TARE at negative gross
value
3
Execute /
Execute
*
0
Not to output unstable or overload data.
Effective in key mode.
Cf05
Output overload and
unstable data
1
To output data always.
GROSS / NET / TARE / Preset TARE
*
0
GR / NT / TR /
TR
1
GR / NT / TR /
PT
Cf06
Header 2
2
G_
/ N_ / T_ /
PT (_: Space 20h)
*
0
Two digits
Cf07
Number of unit digits
1
Three digits
Serial output data
*
0
Not used (Ineffective)
Cf08
Accumulation function
1
Used (Effective)
*
0
Used (Effective)
Cf09
Preset Tare (PT)
1
Not used (Ineffective)
CAP : Maximum capacity
*: Initial settings
Power on ZERO (CF02)
Cf02
=
0
After power on, the weight display starts immediately.
Cf02
=
1
,
2
,
3
When the zero range is exceeded at power on,
------
is displayed.
Press
the
ESC
key to start the weight display.
6.3. CF-Functions