ENGLISH
40
19 CABLE LAYING DIAGRAM
3 x 1,5
4 x 0,8
2 x 0,8
4 x 0,8
1
4
4
7
3
2
8
6
3
7
13
5
5
2 x 0,8
4 x 0,8
11
9
10
12
3 x 1,5 *
14
NYY 3 x 1,5 *
230 VAC
max. 100 mm vor
dem Schiebetor
max. 250 mm vom Boden
entfernt montieren
Max. 100 mm in front
of the sliding gate
Install max. 250 mm from
the ground
Cable laying diagram
1
Sliding opener
2
Gear rack
3
Limit switch bracket with magnet
4
Light barrier type 2 (external)/transmitter
(TX) and receiver (RX)
5
Light barrier type 1 (internal)/transmitter
(TX) and receiver (RX)
6
Key switch/command unit
7
Mechanical end stop, open/close
(overrun protection)
8
Warning light/fl ashing light with fl asher
unit/warning beacon
9
Safety contact strip, 8k2, mobile, main
closing edge in close direction
10
Safety contact strip, 8k2, mobile, main
closing edge in open direction
11
Safety contact strip, 8k2, stationary,
secondary closing edge in open direction
12
Safety contact strip, 8k2, stationary,
secondary closing edge in close direction
13
Handheld transmitter
14
Main switch, all-pole-disconnecting and
lockable