ENGLISH
39
J1-J4
Command input (START) for key switch, push button
(fl oating normally open contact)
J2-J4
Command input (START P) for partial opening
(fl oating normally open contact)
J3-J4
STOP input (fl oating normally closed contact)
J4
Common earth/ground (GND)
J5-J9
Light barrier type 1 (fl oating normally closed contact),
active in open and close direction
J6-J9
Light barrier type 2 (fl oating normally closed contact),
active in close direction
J7-J9
Contact strip OPEN (8k2 or fl oating normally closed
contact)
J8-J9
Contact strip CLOSE (8k2 or fl oating normally closed
contact)
J9
Common earth/ground (GND)
E1
Voltage output 24 V DC, max. 400 mA
E2
Voltage output, earth/ground (GND)
E3
Voltage output 24 V DC for function test; deactivated
for test
E4-E5
Warning light connection 24 V DC/max. 3 W
L
L1 of mains supply 230 V AC/50 Hz
N
N of mains supply 230 V AC/50 Hz
B1-B2
Lighting (fl oating option relay)
F1
Microfuse 2 A (safeguard for 230 V AC circuit)
MAINS
Operating LED, lights up when voltage present
OVERLOAD
Overload indicator for 24 V AC output, lights up on
overload
ADI
ADI interface for additional modules
"Up" function button or START
OK
OK function button
"Down" function button or START P
Factory set connections, must not be modifi ed
1
Voltage supply of control 24 V DC
2
Encoder connection
3
Reed contact connection (end position sensor)
4
Motor connection