ENGLISH
29
8
OPERATION
WARNING!
Risk of injury when the gate is
moving!
A moving gate can give rise to injury or
damage in the gate area.
• Children must not play with the gate
system.
• Ensure that no persons or objects are
located within the movement area of
the gate.
• Ensure that no persons or objects are
located between the gate and opener
mechanism.
• In the event that the gate system is equipped with only one
safety device, operate the sliding opener only when you can
clearly see the movement area of the gate.
• Monitor movement of the gate until it has reached its end
position.
• Only pass or walk through gate openings of remote-
controlled gate systems if the gate is in the gate open end
position!
WARNING!
Danger of crushing and shearing
When the gate is moving, there is a risk fi ngers or limbs
becoming crushed or severed by the gear rack or between the
gate and closing edge.
• Never grab hold of the gear rack, gear wheel or main/
secondary closing edges when the gate is moving!
8.1
Instructing personnel
• Instruct all personnel who use the gate system on how to
operate the system properly and safely.
• Demonstrate and test the mechanical release as well as the
safety recoil.
8.2
Function check
• Test the function of the mechanical
release and safety recoil on a
monthly
basis.
•
Check the safety recoil
: actuate the
closing edge protection when the gate
is closing and opening.
The gate system must start the safety
recoil.
• In the event that the safety recoil fails, an expert must be
commissioned immediately to check and repair if necessary.
8.3
Conduct in the event of/following a power failure
WARNING!
Risk of injury from unexpected gate movement
The power supply to the system must be switched off before
each release and locking action. This prevents an unintended
pulse from moving the gate.
• When performing work on the gate system, switch off the
mains supply and secure it against unauthorised
re-activation.
In order to open or close the gate by hand in the event of a power
failure, it must be released from the opener. See also
"Actuating
the emergency release" on page 11
.
Note
Slide the gate until shortly ahead of the "gate open" end
position and release the opener to allow the next start
command to start the reference run following the power failure.
The opener then closes at minimum speed until the "gate
closed" limit switch is reached.
Failure to do so can prevent
the gate from opening or closing
fully following the power failure.
Figure 23 - Releasing the opener in the event of a power failure
Auf
Zu
Zu
Auf
23
Summary of Contents for CX1024
Page 1: ...www 4ddoors com au instructions for fitting operating and maintenance Sliding operator CX1024 ...
Page 2: ...2 A B Ø 12 mm Ø 5 5 mm 17 mm 3 mm 2 17 5 mm 3 mm PIC 01 ...
Page 12: ...ENGLISH 12 DX SX DX SX 11 Figure 11 End positions Max 38 mm 102 mm 12 Figure 12 Distances ...
Page 37: ...ENGLISH 37 ...