7.24 Photocell 1 input (terminals J5/J9)
This menu allows you to activate light barrier type 1. This light barrier is active on
opening and closing, a gate movement is stopped immediately and prevented until the
light barrier is released.
The light barrier is installed inside the gate.
nEin
The input is deactivated.
Input bridging is not necessary.
JA
The input is activated.
7.25 Photocell 2 input (terminals J6/J9)
This menu allows you to activate light barrier type 2. This light barrier is active on
closing and when the gate is stationary and is installed in front of the gate (outside).
AUS
The input is deactivated.
Input bridging is not necessary.
ZUPA
The input is active on closing; gate closing is stopped immediately if the light
barrier is passed and the gate is opened again. In addition, the light barrier is
also active when the gate is stationary, i.e. if the light barrier is passed when
the gate is stationary, the gate cannot be opened or closed.
ZU
The input is only active on closing.
7.26 Testing the safety devices
This menu allows you to activate testing of the connected safety devices. When this
option is activated, the function test is performed before each gate cycle. In the event
that a malfunction is detected, no gate movement takes place and the warning light
lights up for
5 sec
.
nEIn
Function is deactivated.
JA
Testing is activated for light barriers.
Note
Activate light barrier testing to increase safety.
7.27 Closing edge protection 1 (terminals J7/J9) input
This menu allows you to activate the closing edge protection type 1 input. The input is
only active in the open direction.
nEin
The input is deactivated.
Input bridging is not necessary.
JA
The input is activated.
OK
OK
OK
Ï
Ï
Ï
Ð
Ð
Ð
OK
OK
OK
OK
Ï
Ï
Ï
Ï
Ð
Ð
Ð
Ð
OK
OK
OK
Ï
Ï
Ï
Ð
Ð
Ð
OK
OK
OK
Ï
Ï
Ï
Ð
Ð
Ð
Summary of Contents for CX1024
Page 1: ...www 4ddoors com au instructions for fitting operating and maintenance Sliding operator CX1024 ...
Page 2: ...2 A B Ø 12 mm Ø 5 5 mm 17 mm 3 mm 2 17 5 mm 3 mm PIC 01 ...
Page 12: ...ENGLISH 12 DX SX DX SX 11 Figure 11 End positions Max 38 mm 102 mm 12 Figure 12 Distances ...
Page 37: ...ENGLISH 37 ...