Problems That Occur Before Connecting
17-3
Double characters are appearing on your monitor
This is a signal that both the Courier V.Everything modem's local echo
and your software's local echo are on.
Type the command to turn off your online echo (ATF1) or turn your
communications software's local echo off (refer to your software's
documentation).
After you dial, the Courier V.Everything modem reports NO CARRIER and then hangs up
■
Try increasing S7 and decreasing S9 to allow more time for the
connection
■
Try calling a different device. If you are trying to connect to an older
modem at 2400 bps or less, it may not support error control. Try
sending AT&M0, and then try the call again. Reset the Courier
V.Everything modem (send ATZ) after you finish the call.
Hear ringing but the Courier V.Everything modem won't answer
■
For external Courier V.Everything modems, look at the TR LED to make
sure that your terminal or computer is sending a DTR signal via the
EIA-232 interface.
■
Send ATI4 to the Courier V.Everything modem and check that S0 is set
to a value higher than 0. Also, check that DIP switch 5 is OFF.
■
Set &F1 and S0=1, then try again.
The Courier V.Everything modem
acts as though a data link has been established, but no
call was received
Carrier Detect (CD) may be overridden (with &C0), but your system may
require that the override be turned OFF (with &C1). Review your
communications software manual to see what CD operations are
required.
The Courier V.Everything modem
behaves as if Enter were pressed when you don't press
any keys
Your software may be misreading signals from the Courier V.Everythin
modem when the Courier V.Everything modem sends a Carriage Return
Summary of Contents for Courier
Page 12: ......
Page 28: ...1 14 CHAPTER 1 CONNECTING TO YOUR ISP ...
Page 36: ...3 4 CHAPTER 3 UPGRADING YOUR MODEM ...
Page 58: ...6 6 CHAPTER 6 WORKING WITH MEMORY ...
Page 64: ...8 4 CHAPTER 8 CONTROLLING EIA 232 SIGNALING ...
Page 72: ...9 8 CHAPTER 9 ACCESSING AND CONFIGURING THE COURIER V EVERYTHING MODEM REMOTELY ...
Page 80: ...10 8 CHAPTER 10 CONTROLLING DATA RATES ...
Page 96: ...12 6 CHAPTER 12 FLOW CONTROL ...
Page 108: ...13 12 CHAPTER 13 HANDSHAKING ERROR CONTROL DATA COMPRESSION AND THROUGHPUT ...
Page 112: ...14 4 CHAPTER 14 DISPLAYING QUERYING AND HELP SCREENS ...
Page 122: ...15 10 CHAPTER 15 TESTING THE CONNECTION ...
Page 142: ...17 8 CHAPTER 17 TROUBLESHOOTING ...
Page 156: ...A 14 APPENDIX A S REGISTERS ...
Page 172: ...B 16 APPENDIX B ALPHABETIC COMMAND SUMMARY ...
Page 178: ...C 6 APPENDIX C FLOW CONTROL TEMPLATE ...
Page 186: ...E 4 APPENDIX E V 25 BIS REFERENCE ...