2N TELEKOMUNIKACE a.s., www.2n.cz
304/377
Tip
Click Load calls from archive in the Calls menu to load the secondary call
database.
Warning
If you set the parameters to the minimum value (3 days), all calls will be
deleted irretrievably after being moved to the secondary database.
Line
Complete the line parameters, select Active and save the new settings to activate a
new SIP line. This activates the Registration result and sends the registration packet.
The registration result is then displayed and the identification in the list changes from
No to Yes. See below for details.
Note
Enter
and
at least to configure a
SIP Server, Registrar server
Username
valid SIP line.
Select/unselect Active to activate/deactivate the selected line. Enter the SIP Proxy
address into the SIP Server:Port field. The port is optional. If you set just the Proxy
address, the default port 5060 is used. If you choose another port, add this port
behind a colon. Enter the SIP Proxy address for login into the Registrar server
parameter. The port is optional. If you set just the Proxy address, the default port
5060 is used. If you choose another port, add this port behind a colon. Domain
specifies Proxies within one SIP server. Unless specified otherwise by your provider,
the domain will be SIP or Registrar server, yet without a port. See the figure above.
Complete the Username for your SIP Proxy server authentication and Password if the
Proxy requires so. Registration expires after is an optional parameter. The default
value is 300 s, but some servers may require a different value, which will not be
changed. Set the Timeout – DTMF in seconds: 120 s is the default value. If no DTMF
arrives within this timeout after answer, the call will be terminated. Registration result
displays the SIP Proxy registration result. If unsuccessful. the registration packet will
be resent. This parameter is updated automatically. When you click Save for
Summary of Contents for Lift8
Page 1: ...www 2n cz 2N Lift8 Communicator for lifts User Manual Firmware Version 2 3 1 ...
Page 28: ...2N TELEKOMUNIKACE a s www 2n cz 28 377 Indication Elements ...
Page 40: ...2N TELEKOMUNIKACE a s www 2n cz 40 377 Examples of Connection ...
Page 70: ...2N TELEKOMUNIKACE a s www 2n cz 70 377 ...
Page 95: ...2N TELEKOMUNIKACE a s www 2n cz 95 377 ...
Page 136: ...2N TELEKOMUNIKACE a s www 2n cz 136 377 User name Admin Password 2n ...
Page 202: ...2N TELEKOMUNIKACE a s www 2n cz 202 377 Connection two cabin lift ...
Page 210: ...2N TELEKOMUNIKACE a s www 2n cz 210 377 ...