2N TELEKOMUNIKACE a.s., www.2n.cz
159/377
Par.
No
Parameter name
Range of values
Default value
Note
Info
087
Insert specific
character in
fault reporting
memory
088
Count of
automatic
dialling cycles
for ERROR
0–9
3
181–
186
Confirmation
mode for
number 1–6
3–9
5
3 = CPC Antenna,
4= CPC KONE,
5 = P100,
6 = autodetection DTMF
protocol (CPC Antenna
/P100)
If there is no guarantee of
problem-free transfer of
DTMF, do not set 6 for
autodetection CPC
Antenna/P100, but
precisely specify the
protocol to be used (3 or
5).
501
Default output
state of IO
module 1
ABCD
empty
The value defines the
state of the I/O modules
after the system start:
A= output 1
B= output 2
C= output 3
D= output 4
0= output off
1= output on
From
version
1.6.0
502
Default output
state of IO
module 2
ABCD
empty
503
Default output
state of IO
module 3
ABCD
empty