Chapter 34 Access Control
GS1350 Series User’s Guide
281
reset
zySysMgmtUncontrolledSyste
mReset
1.3.6.1.4.1.890.1.15.3.49.2.1
This trap is sent when the Switch
automatically resets.
zySysMgmtControlledSystem
Reset
1.3.6.1.4.1.890.1.15.3.49.2.2
This trap is sent when the Switch resets by
an administrator through a management
interface.
zySysMgmtBootImageIncons
istence
1.3.6.1.4.1.890.1.15.3.49.2.3
This trap is sent when the index number of
image which is loaded when the Switch
starts up is different from what is specified
via the CLI.
RebootEvent
1.3.6.1.4.1.890.1.5.1.1.2
This trap is sent when the Switch reboots by
an administrator through a management
interface.
timesync
zyDateTimeTrapTimeServerN
otReachable
1.3.6.1.4.1.890.1.15.3.82.3.1
This trap is sent when the Switch’s date and
time is not manually entered or the
specified time server is not reachable.
zyDateTimeTrapTimeServerN
otReachableRecovered
1.3.6.1.4.1.890.1.15.3.82.3.2
This trap is sent when the Switch’s real time
clock is up to date.
intrusionlock
zyPortIntrusionLock
1.3.6.1.4.1.890.1.15.3.61.3.2
This trap is sent when intrusion lock occurs
on a port.
loopguard
zyLoopGuardLoopDetect
1.3.6.1.4.1.890.1.15.3.45.2.1
This trap is sent when loopguard shuts down
a port.
errdisable
zyErrdisableDetect
1.3.6.1.4.1.890.1.15.3.24.4.1
This trap is sent when an error is detected
on a port, such as a loop occurs or the rate
limit for specific control packets is
exceeded.
zyErrdisableRecovery
1.3.6.1.4.1.890.1.15.3.24.4.2
This trap is sent when the Switch ceases the
action taken on a port, such as shutting
down the port or discarding packets on the
port, after the specified recovery interval.
poe
(For PoE models
only)
zyPoePowerPortOverload
1.3.6.1.4.1.890.1.15.3.59.4.1
This trap is sent when the port is turned off to
supply power due to overloading.
zyPoePowerPortShortCircuit
1.3.6.1.4.1.890.1.15.3.59.4.2
This trap is sent when the port is turned off to
supply power due to short circuit.
zyPoePowerPortOverSystem
Budget
1.3.6.1.4.1.890.1.15.3.59.4.3
This trap is sent when the port is turned off to
supply power because the requested
power exceeds the total PoE power
budget on the Switch.
zyPoePowerPortOverloadRe
covered
1.3.6.1.4.1.890.1.15.3.59.4.5
This trap is sent when the port is turned on to
recover from an overloaded state.
zyPoePowerPortShortCircuitR
ecovered
1.3.6.1.4.1.890.1.15.3.59.4.6
This trap is sent when the port is turned on to
recover from a short circuit.
zyPoePowerPortOverSystem
BudgetRecovered
1.3.6.1.4.1.890.1.15.3.59.4.7
This trap is sent when the port is turned on to
recover from an over system budget.
loginrecord
zyAccessControlLoginRecor
d
1.3.6.1.4.1.890.1.15.3.9.4.1
This trap is sent when users log in.
zyAccessControlLogoutRec
ord
1.3.6.1.4.1.890.1.15.3.9.4.2
This trap is sent when users log out.
zyAccessControlLoginFail
1.3.6.1.4.1.890.1.15.3.9.4.3
This trap is sent when users fail in login.
Table 140 SNMP System Traps (continued)