9-8
System Cards
Model No.
Running Head
WAN Card Descriptions
WAN Card
Figure 9-6.WAN Download Options
To download the new software, use the arrow key to move over to the 'dnload' option. The user
will be presented with a question: "Are you sure you want to overwrite this block (y/n)?".
Select 'y' to confirm the process. New in release 6.1.2, after the user confirms that the
download is desired, the system will raise an UPGRADE alarm, noting the WAN card being
upgraded. The user will then be presented with the option to use XMODEM or TFTP. The
XMODEM option is supported only via a direct connection to the IMACS unit. Should the
customer attempt to use the XMODEM option on a telnet session, the IMACS will respond
with "Error, a modem connection is needed to start the XMODEM transfer…".In this case,
you must choose the TFTP option. The upgrade will take approximately three minutes,
depending on latency in the network. The user must have a TFTP server set up in order to
choose the TFTP process. If the user chooses an option they wish to change, simply hit cntl-x
to abort the loading function.
TFTP download process
Once TFTP has been chosen, the user will be presented a series of questions. Use the defaults
when prompted. Following are the questions and the correct way to initiate the download:
Mismatch retries: Hit carriage return to select the default value of 20.
Timeout retries: Hit carriage return to select the default value of 4.
IP Address of server: Enter the IP address for the TFTP server which is pointing to the location
for the new WAN load.
Содержание IMACS 8000
Страница 20: ...xviii Table of Contents Model No Running Head Table of Contents...
Страница 38: ...1 6 Reference Guide Model No Running Head Customer Service and Ordering Information What s New...
Страница 58: ...2 20 Reference Guide Model No Running Head Installing the Other Plug In Cards System Installation...
Страница 82: ...4 18 Reference Guide Model No Running Head PWE IP Uplink Server 8000 PWE Applications...
Страница 210: ...6 12 Reference Guide Model No Running Head Performance Monitoring System Testing and Diagnostics...
Страница 270: ...7 60 System Cards Model No Running Head CPU Card Specifications CPU Card...
Страница 300: ...8 30 System Cards Model No Running Head Interface Card Specifications Interface Card...
Страница 337: ...System Cards 9 37 WAN Card WAN Card User Screens and Settings Figure 9 21 T1 WAN Cross Connect Screen display only...
Страница 352: ...9 52 System Cards Model No Running Head WAN Card Specifications WAN Card...
Страница 360: ...10 8 System Cards Model No Running Head Alarm Card Troubleshooting Alarm Cards...
Страница 382: ...11 22 Voice Cards Model No Running Head E M Card Specifications E M Card...
Страница 454: ...14 34 Data Cards Model No Running Head HSU Card User Screens and Settings HSU Card Figure 14 16 HSU Broadcast Screen...
Страница 474: ...14 54 Data Cards Model No Running Head HSU Card Specifications HSU Card...
Страница 484: ...15 10 Data Cards Model No Running Head OHSU Card Specification OHSU 4P Card...
Страница 536: ...18 8 Data Cards Model No Running Head DS0 DP Card Specifications DS0 DP Card...
Страница 596: ...21 38 Server Cards Model No Running Head IPR 4 Server Card Specifications IPR 4 Router Card...
Страница 614: ...22 18 Server Cards Model No Running Head ACS MCC Card Troubleshooting MCC Card...
Страница 644: ...24 18 Server Cards Model No Running Head PWE Card Troubleshooting PWE Card...
Страница 659: ...Reference Guide A 15 A 4 2 External Talk Battery Fuses Manufacturer Part NumberA3 Little Fuse 218 005 Bussman GDC 5...
Страница 674: ...A 30 Reference Guide Model No Running Head...
Страница 729: ...Pin Outs C 31 C 8 HSU Cards...
Страница 752: ...C 54 Pin Outs Model No Running Head...