16-8
Data Cards
Model No.
Running Head
LD-SRU Card User Screens and Settings
LDSRU-10P Card
Figure 16-4.SRU Time Slot Integration
SR TS
The Subrate Time Slot (SR TS) indicates the subrate position within the DS0 time slot the port
will occupy (see Figure 16-4). If a framing is selected, only one subrate time slot is supported
and the SR TS setting will default to 1. If b-5 framing is selected, the available subrate time
slots are 1 to 5. If adpcm or hlink are chosen for the frame parameter, this field will show n/a.
In b-5 framing, if circuits with speeds greater than 9.6 kbps are assigned to the subrate time
slot, adjacent subrate time slots must be available to accommodate their size. A 19.2 kbps
circuit would occupy two contiguous subrate time slots (leaving space for up to three 9.6 kbps
circuits) and a 38.4 kbps circuit would occupy four contiguous subrate time slots (leaving
space for one 9.6 kbps circuit).
The SR TS number selected will be the first segment occupied by this circuit. If a 28.8 kbps
circuit occupies three segments of the b-5 frame, selecting SR TS 1 will assign it to segments
1, 2 and 3. Segments 4 and 5 may be assigned either independently to 9.6 (or less) kbps circuits
in SR TS 4 and 5 or combined for a 19.2 kbps circuit assigned to SR TS 4.
If a circuit exceeds the slots necessary to accommodate it, such as a 38.4 kbps circuit to SR
TS 3 in b-5 framing, the message "Invalid SR TS" will be displayed. If a circuit requires more
space than the SR TS has available, such as having a 38.4 kbps circuit in SR TS 1 and then
attempting to assign a 19.2 kbps circuit to SR TS 4, the message "SR TS overlapping" will be
displayed.
increments (i.e. a 19.2Kbps circuit would take SRU timeslots #1 and #2)
Содержание IMACS 8000
Страница 20: ...xviii Table of Contents Model No Running Head Table of Contents...
Страница 38: ...1 6 Reference Guide Model No Running Head Customer Service and Ordering Information What s New...
Страница 58: ...2 20 Reference Guide Model No Running Head Installing the Other Plug In Cards System Installation...
Страница 82: ...4 18 Reference Guide Model No Running Head PWE IP Uplink Server 8000 PWE Applications...
Страница 210: ...6 12 Reference Guide Model No Running Head Performance Monitoring System Testing and Diagnostics...
Страница 270: ...7 60 System Cards Model No Running Head CPU Card Specifications CPU Card...
Страница 300: ...8 30 System Cards Model No Running Head Interface Card Specifications Interface Card...
Страница 337: ...System Cards 9 37 WAN Card WAN Card User Screens and Settings Figure 9 21 T1 WAN Cross Connect Screen display only...
Страница 352: ...9 52 System Cards Model No Running Head WAN Card Specifications WAN Card...
Страница 360: ...10 8 System Cards Model No Running Head Alarm Card Troubleshooting Alarm Cards...
Страница 382: ...11 22 Voice Cards Model No Running Head E M Card Specifications E M Card...
Страница 454: ...14 34 Data Cards Model No Running Head HSU Card User Screens and Settings HSU Card Figure 14 16 HSU Broadcast Screen...
Страница 474: ...14 54 Data Cards Model No Running Head HSU Card Specifications HSU Card...
Страница 484: ...15 10 Data Cards Model No Running Head OHSU Card Specification OHSU 4P Card...
Страница 536: ...18 8 Data Cards Model No Running Head DS0 DP Card Specifications DS0 DP Card...
Страница 596: ...21 38 Server Cards Model No Running Head IPR 4 Server Card Specifications IPR 4 Router Card...
Страница 614: ...22 18 Server Cards Model No Running Head ACS MCC Card Troubleshooting MCC Card...
Страница 644: ...24 18 Server Cards Model No Running Head PWE Card Troubleshooting PWE Card...
Страница 659: ...Reference Guide A 15 A 4 2 External Talk Battery Fuses Manufacturer Part NumberA3 Little Fuse 218 005 Bussman GDC 5...
Страница 674: ...A 30 Reference Guide Model No Running Head...
Страница 729: ...Pin Outs C 31 C 8 HSU Cards...
Страница 752: ...C 54 Pin Outs Model No Running Head...