System Cards
9-49
WAN Card
WAN Card Specifications
CSU Interface
Bit Rate and Tolerance
1.544 Mbps + 32 ppm
No. of T1 WAN Links per module
1
Max. No. per WAN card
2
Electrical Interface
Per ANSI T1.102/T1.403, DSX-1 100
1/2
balanced
Transmission Range
Software Selectable - 0 dB, 7.5 dB, 15 dB
3000 feet to 6000 feet with 40 dB cable loss (@ 5000 ft. or 1500 m)
Actual range depends on cable characteristics although software
selectable ranges of 0 dB, 7.5 dB and 15 dB are provided. (0 - allows
connection to the network side of a co-located external CSU over a
short-distance, four-wire cable)
Line Coding
Software Selectable AMI or B8ZS
Frame Format
Software Selectable - D4, ESF, SLC96, Subscriber Loop Carrier D4
D4 Framing
Normal Superframe
ESF Framing
Extended Superframe
Subscriber Loop Carrier 96
As per TR-TSY-000008 Mode 1
Supports logical shelf A, logical shelf B or logical shelf group AB only
Supports POTS, CLASS services, CENTREX services, Loop and
Ground Start FXS and FX trunks and DID circuits
Does not support Multi-Party or Coin Phone lines
Subscriber Loop Carrier D4
Supports SP/UVG signaling
Supports shelf group B only
Voice Channel Signaling
AT&T PUB 43801, AT&T 62411, ITU-T Q.421, Q.422 using
Robbed-bit method
Error Detection
Frame Format
Error Scheme
ESF
CRC-6, Controlled Slip, Out of Frame
D4, SLC96, SLCD4
BiPolar Violation, Controlled Slip, Out of Frame
Alarm Indication
As per Bellcore TR-TSY-000191
SLIP Limit
Software Selectable: 126 bits or 138 bits
Equalization
Software Selectable with settings for 0, 7.5 or 15.0 dB
Power Levels
Complies with ANSI T1.403 and ITU-T G.703
Output Jitter
Complies with ITU-T G.824
Input Jitter and Wander
Complies with ITU-T G.824
Содержание IMACS 8000
Страница 20: ...xviii Table of Contents Model No Running Head Table of Contents...
Страница 38: ...1 6 Reference Guide Model No Running Head Customer Service and Ordering Information What s New...
Страница 58: ...2 20 Reference Guide Model No Running Head Installing the Other Plug In Cards System Installation...
Страница 82: ...4 18 Reference Guide Model No Running Head PWE IP Uplink Server 8000 PWE Applications...
Страница 210: ...6 12 Reference Guide Model No Running Head Performance Monitoring System Testing and Diagnostics...
Страница 270: ...7 60 System Cards Model No Running Head CPU Card Specifications CPU Card...
Страница 300: ...8 30 System Cards Model No Running Head Interface Card Specifications Interface Card...
Страница 337: ...System Cards 9 37 WAN Card WAN Card User Screens and Settings Figure 9 21 T1 WAN Cross Connect Screen display only...
Страница 352: ...9 52 System Cards Model No Running Head WAN Card Specifications WAN Card...
Страница 360: ...10 8 System Cards Model No Running Head Alarm Card Troubleshooting Alarm Cards...
Страница 382: ...11 22 Voice Cards Model No Running Head E M Card Specifications E M Card...
Страница 454: ...14 34 Data Cards Model No Running Head HSU Card User Screens and Settings HSU Card Figure 14 16 HSU Broadcast Screen...
Страница 474: ...14 54 Data Cards Model No Running Head HSU Card Specifications HSU Card...
Страница 484: ...15 10 Data Cards Model No Running Head OHSU Card Specification OHSU 4P Card...
Страница 536: ...18 8 Data Cards Model No Running Head DS0 DP Card Specifications DS0 DP Card...
Страница 596: ...21 38 Server Cards Model No Running Head IPR 4 Server Card Specifications IPR 4 Router Card...
Страница 614: ...22 18 Server Cards Model No Running Head ACS MCC Card Troubleshooting MCC Card...
Страница 644: ...24 18 Server Cards Model No Running Head PWE Card Troubleshooting PWE Card...
Страница 659: ...Reference Guide A 15 A 4 2 External Talk Battery Fuses Manufacturer Part NumberA3 Little Fuse 218 005 Bussman GDC 5...
Страница 674: ...A 30 Reference Guide Model No Running Head...
Страница 729: ...Pin Outs C 31 C 8 HSU Cards...
Страница 752: ...C 54 Pin Outs Model No Running Head...