Reference Guide
4-13
Applications
Data Modules and Applications
An OCU-DP port may be programmed for OCU mode or CSU mode. OCU mode is the most
common and is used whenever the OCU-DP port attaches to a CSU/DSU over a four-wire
circuit. CSU mode allows the card to be connected directly to the digital network.
Software initiated diagnostics supported by the OCU-DP card include the setting of six
different loop backs. Three of these act on the OCU-DP card itself and are known as local loop
backs and the other three generate loop back patterns to remote devices and are known as
remote loop backs. Among local loop backs, there are three types:
•
loop backs of the 4-wire analog interface of the OCU-DP port towards the attached CSU
•
loop backs of the 4-wire OCU-DP interface towards the network
•
loop backs towards the network at the point where the OCU-DP card interfaces with the
system bus
All three remote loop backs are latching loop backs. These latching loop backs are:
•
loop back of the analog interface of the remote OCU-DP device back towards the
network
•
loop back of the 4-wire interface of the remote CSU device back towards the network
•
loop backs of the 4-wire interface of the local CSU device towards the network.
An OCU-DP port may be programmed to detect and respond to both latching and non-latching
(i.e., alternating) DDS-format OCU loop back codes that are initiated from the remote end of
the circuit. A time-out option authorizes the OCU-DP port to automatically release the loop
back after ten minutes.
4.3.6
DSO-DP Card
The 8000-DS0DP-4P DSO Data Port/G.703 Data Unit (DSO-DP/G.703) is a plug-in user card
for the system. The DSO-DP/G.703 provides a 64 Kbps interface to a DSO of a T1/E1
network. The card supports four (4) ports each of which provide a 64 Kbps interface to a DSO
on a T1 or E1 WAN link. Each DSO-DP/G.703 card can be installed in any User Slot and
provides four (4) DB15 female connectors.
The DSO-DP/G.703 card can be programmed to operate in either DSO-DP mode or in G.703
mode. In G.703 mode, the card supports either co-directional or contra-directional operation
and that option is set-able on a port-by-port basis. In DS0-DP mode, in addition to Transmit
Data and Receive Data, the card can be programmed to either provide a 64 Kbps bit clock and
an 8 kHz byte clock to the attached device or to receive those two clocks from the attached
device.
Содержание IMACS 8000
Страница 20: ...xviii Table of Contents Model No Running Head Table of Contents...
Страница 38: ...1 6 Reference Guide Model No Running Head Customer Service and Ordering Information What s New...
Страница 58: ...2 20 Reference Guide Model No Running Head Installing the Other Plug In Cards System Installation...
Страница 82: ...4 18 Reference Guide Model No Running Head PWE IP Uplink Server 8000 PWE Applications...
Страница 210: ...6 12 Reference Guide Model No Running Head Performance Monitoring System Testing and Diagnostics...
Страница 270: ...7 60 System Cards Model No Running Head CPU Card Specifications CPU Card...
Страница 300: ...8 30 System Cards Model No Running Head Interface Card Specifications Interface Card...
Страница 337: ...System Cards 9 37 WAN Card WAN Card User Screens and Settings Figure 9 21 T1 WAN Cross Connect Screen display only...
Страница 352: ...9 52 System Cards Model No Running Head WAN Card Specifications WAN Card...
Страница 360: ...10 8 System Cards Model No Running Head Alarm Card Troubleshooting Alarm Cards...
Страница 382: ...11 22 Voice Cards Model No Running Head E M Card Specifications E M Card...
Страница 454: ...14 34 Data Cards Model No Running Head HSU Card User Screens and Settings HSU Card Figure 14 16 HSU Broadcast Screen...
Страница 474: ...14 54 Data Cards Model No Running Head HSU Card Specifications HSU Card...
Страница 484: ...15 10 Data Cards Model No Running Head OHSU Card Specification OHSU 4P Card...
Страница 536: ...18 8 Data Cards Model No Running Head DS0 DP Card Specifications DS0 DP Card...
Страница 596: ...21 38 Server Cards Model No Running Head IPR 4 Server Card Specifications IPR 4 Router Card...
Страница 614: ...22 18 Server Cards Model No Running Head ACS MCC Card Troubleshooting MCC Card...
Страница 644: ...24 18 Server Cards Model No Running Head PWE Card Troubleshooting PWE Card...
Страница 659: ...Reference Guide A 15 A 4 2 External Talk Battery Fuses Manufacturer Part NumberA3 Little Fuse 218 005 Bussman GDC 5...
Страница 674: ...A 30 Reference Guide Model No Running Head...
Страница 729: ...Pin Outs C 31 C 8 HSU Cards...
Страница 752: ...C 54 Pin Outs Model No Running Head...