![Zhone IMACS 8000 Скачать руководство пользователя страница 63](http://html1.mh-extra.com/html/zhone/imacs-8000/imacs-8000_user-manual_3745919063.webp)
Reference Guide
3-5
IMACS 8000 Chassis Description
Chassis
Table 3-1 shows the card slots for the 8000-CHASSIS.
Table 3-1. Card Slots for the 8000-CHASSIS
Type of Card
# of
Cards
Slots Used
Notes
CPU
1 or 2
C1, C2
One required in either slot
Server
1 to 3
P1, P2, P3
ADPCM, IPR*4, OC3, PWE and Bridge
WAN
1 to 4
W1-W4
Up to four.
Interface
1
IF
Required
Alarm
0 to 8
U1-U8
Internal/External, any user slot
E&M Voice
0 to 8
U1-U8
2/4-wire voice, any user slot
FXS Voice
0 to 8
U1-U8
2-wire voice, any user slot
FXO Voice
0 to 8
U1-U8
2-wire voice, any user slot
DS0-DP Data
0 to 8
U1-U8
The DS0-DP card Contra directional/Codirectional Data Unit
(DS0-DP/G.703) provides a 64 kbps interface to a DS0 time
slot of a T1 or E1 network. This is a 4-wire data card and
inserts into any user card slot.
HSU Data
0 to 8
U1-U8
High-speed data, any user slot
OHSU Data
0 to 8
U1-U8
High-speed data, any user slot
OCU-DP Data
0 to 8
U1-U8
The Office Channel Unit - Dataport cards interface directly
with Data Service Units/Channel Service Units (DSU/CSUs)
support data traffic up to an including 64 kbps. This is a
4-wire data card and inserts into any user card slot.
SRU Data
0 to 8
U1-U8
Sub-rate data, any user slot
Main Power
(AC/DC)
1 or 2
F1, F2
AC or DC power supplies
Optional Power
0 to 2
NS1-NS2
AC-to-DC converter (-48V) 100W
Optional Ringer
0 to 2
R1-R2
Ringing generator
Содержание IMACS 8000
Страница 20: ...xviii Table of Contents Model No Running Head Table of Contents...
Страница 38: ...1 6 Reference Guide Model No Running Head Customer Service and Ordering Information What s New...
Страница 58: ...2 20 Reference Guide Model No Running Head Installing the Other Plug In Cards System Installation...
Страница 82: ...4 18 Reference Guide Model No Running Head PWE IP Uplink Server 8000 PWE Applications...
Страница 210: ...6 12 Reference Guide Model No Running Head Performance Monitoring System Testing and Diagnostics...
Страница 270: ...7 60 System Cards Model No Running Head CPU Card Specifications CPU Card...
Страница 300: ...8 30 System Cards Model No Running Head Interface Card Specifications Interface Card...
Страница 337: ...System Cards 9 37 WAN Card WAN Card User Screens and Settings Figure 9 21 T1 WAN Cross Connect Screen display only...
Страница 352: ...9 52 System Cards Model No Running Head WAN Card Specifications WAN Card...
Страница 360: ...10 8 System Cards Model No Running Head Alarm Card Troubleshooting Alarm Cards...
Страница 382: ...11 22 Voice Cards Model No Running Head E M Card Specifications E M Card...
Страница 454: ...14 34 Data Cards Model No Running Head HSU Card User Screens and Settings HSU Card Figure 14 16 HSU Broadcast Screen...
Страница 474: ...14 54 Data Cards Model No Running Head HSU Card Specifications HSU Card...
Страница 484: ...15 10 Data Cards Model No Running Head OHSU Card Specification OHSU 4P Card...
Страница 536: ...18 8 Data Cards Model No Running Head DS0 DP Card Specifications DS0 DP Card...
Страница 596: ...21 38 Server Cards Model No Running Head IPR 4 Server Card Specifications IPR 4 Router Card...
Страница 614: ...22 18 Server Cards Model No Running Head ACS MCC Card Troubleshooting MCC Card...
Страница 644: ...24 18 Server Cards Model No Running Head PWE Card Troubleshooting PWE Card...
Страница 659: ...Reference Guide A 15 A 4 2 External Talk Battery Fuses Manufacturer Part NumberA3 Little Fuse 218 005 Bussman GDC 5...
Страница 674: ...A 30 Reference Guide Model No Running Head...
Страница 729: ...Pin Outs C 31 C 8 HSU Cards...
Страница 752: ...C 54 Pin Outs Model No Running Head...