Discover All Fixtures
The Discover all fixtures button discovers and patches all possible fixtures at the point it’s pressed. Although this
usually happens automatically when RigSync is enabled, there are situations when it won’t. For example, if you delete
a fixture that was discovered by RigSync, that fixture won’t be rediscovered and repatched unless you press
Discover all fixtures .
Revert Rig
The Revert rig back button reverts all fixtures to the settings they had when they were first discovered by RigSync.
For example, if the whole rig was DMX Address 1, RigSync will remember those settings (and store them in the
showfile) before automatically changing the DMX addresses so they don’t clash. Selecting Revert rig back will put
all the fixtures back to DMX Address 1, and not automatically change them again.
Lock Rig
By default, Lock Rig is disabled. However when enabled, "Lock rig" instructs RigSync to continuously and
automatically revert any changes which are made to settings on fixtures that could affect the show – such as DMX
Address, Pan/Tilt Settings or Personality/Mode. When changes such as these are made on a fixture, RigSync will
detect them and revert them back. These changes can continue to be made from the console without disabling “Lock
Rig”.
Art-RDM
As well as RigSync using RDM on the DMX ports on the rear of the console to keep your console and fixtures
synchronised, RigSync will also use RDM over Art-Net if Art-Net is enabled.
Click here to find out more about Art-Net.
To go in depth on RDM, take a look at the session below...
Sometimes, you may find that fixtures flicker, with the presence of RDM on the DMX line. If so, then unfortunately
your fixtures are not truly DMX compliant.
To stop the flicker, you will need to remove RDM data from the fixture's DMX line. This can be done by either
disabling RigSync completely, or disabling RigSync just on the DMX port the fixtures are connected to.
Alternatively connect your non-compliant fixtures from a feed of a DMX Splitter with RDM removed.
Contact the fixture's manufacturer, to see if there is a firmware update to solve the flicker.
If you need to remove RDM from a DMX line, Splitter 8 has a switch to
allow you to remove RDM data from the DMX Outputs. Watch the
video to find out more.
Click here to go to the Splitter 8 page.
Zero 88 - ZerOS - Page 181 of 233
Printed: 23/11/2020 12:50:03 JH
Содержание FLX Series
Страница 18: ...Zero 88 ZerOS Page 18 of 233 Printed 23 11 2020 12 50 03 JH...
Страница 96: ...Colour Auto Effect Palettes Zero 88 ZerOS Page 96 of 233 Printed 23 11 2020 12 50 03 JH...
Страница 97: ...Zero 88 ZerOS Page 97 of 233 Printed 23 11 2020 12 50 03 JH...
Страница 197: ...Shortcuts Zero 88 ZerOS Page 197 of 233 Printed 23 11 2020 12 50 03 JH...
Страница 201: ...Zero 88 ZerOS Page 201 of 233 Printed 23 11 2020 12 50 03 JH...
Страница 224: ...Trouble Shooting Zero 88 ZerOS Page 224 of 233 Printed 23 11 2020 12 50 03 JH...