By default the HYD-ES inverter configured to work in “Auto Mode”. When in this configuration the system will
operate as follow:
While “PV Production” > “Home Consumption”
If the battery is not full. HYD-ES inverter will charge the battery.
While “PV Production” < “Home Consumption”
If the battery is not empty HYD-ES inverter will discharge the battery and provide power to the load.
6.4.
Menu
In the main interface, press “Down” button to enter grid/battery parameters page:
Main Interface
Press “Down”
1.Grid(V)
2.AC Current(A)
3.Frequency
4.Batt(V)
5.Batt Chrg Curr.
6.Batt DisChrg Curr.
7.State of Charge
8.Batt Cycles
9.Batt Temp.
In the main interface, press “UP” button to enter PV parameters page:
Main Interface
Press “UP”
1.PV1 Voltage
2.PV1 Current
3.PV1 Power
4.PV2 Voltage
5.PV2 Current
6.PV2 Power
7.Inverter Temp.
In the main interface, press “back” button to enter main menu. The main menu has the following five options: