the following parameters should be set before HYD-ES inverter starts to operate.
1)Set system time
8)*Set min discharge voltage
2)Set country
9)*Set max discharge current
3)Select battery type
10)*Set min protect voltage
4)*Set battery capacity
11)*Set discharge depth
5)*Set max charge voltage
12)*Set empty discharge voltage
6)*Set max charge current
13)*Set full charge voltage
7)*Set max protect voltage
Note: 4)* to 13)* settings should be done only if at step 3 DEFAULT was selected.
1)Set system time
System time format is “20YY-MM-DD-HH-MM-SS”, press “Up” or “Down” to change the 1
st
digit, press “OK” to
confirm the value and move to next the digit, press “Ok” to complete setting. When system time setting is complete,
“Set country” will pop up.
2)Set country
Press “Up” or “Down” to select a country, press “Ok” to complete the country setting. When country setting is
complete, “Set battery type” will pop up.
Code
Country
Code
Country
Code
Country
00
Germany VDE4105
11
France
22
Europe General
01
CEI-021 Internal
12
Poland
23
CEI-021 External
02
Australia
13
Germany BDEW
24
Cyprus
03
SpainRD1699
14
Germany VDE0126
25
India
04
Turkey
15
CEI-016 Italia
26
Philippines
05
Denmark
16
UK G83
27
New Zealand
06
Greece Continent
17
Greece island
28
Brazil
07
Netherland
18
EU EN50438
29
Slovakia VSD
08
Belgium
19
IEC EN61727
30
Slovakia SSE
09
UK G59
20
Korea
31
Slovakia ZSD
10
China
21
Sweden
32
CEI0-21 In Areti
CAUTION
It’s very important to make sure that you have selected the correct country code
according to requirements of local authority.