27 / 45
2)
Set Time-of-use Mode (only for country where this operation mode is allowed)
Time-of-use Mode allow to force a battery charge from the grid even if the PV production is lower than the
household consumption.
Select “2. Set Time-of-use Mode”, and then press “OK” to enter Set Time-of-use mode menù.
Set Time-of-use Mode
Rules. 0: Enabled
From To SOC Charge
02h00m - 04h00m 070% 1000W
Effective date
Dec. 22 - Mar. 21
Weekday select
Mon. Tue. Wed. Thu. Fri. Sat. Sun.
From the menu is possible to program:
At what time the inverter start to charge the battery from the grid
At what time the inverter should stop charging the battery.
UP to what charge percentage the battery shall be charged.
At which power the battery should be charged.
During which month of the year and day of the week this rule should be applied.
You can set multiple Time-of-use rules to meet your more complex requirement. The HYD-ES inverter support 4
rules maximum (rule 0/1/2/3).
3)
Set Timing Mode
Select “3. Set Timing Mode”, and then press “OK” to enter Set Timing mode interface. The menù of “ Timing
Mode” is shown as below. Timing Mode allow to force a battery charge from the grid and to force a battery
discharge at specific time.