11 / 45
3.6.
Mount HYD-ES inverter
Step 1:
Put the mounting bracket properly on the wall, mark these 8 drill holes using a marker pen. Drill 8 holes (drill
bit 6mm)
on the wall.
Step 2:
Insert the expansion screw vertically into the hole, note the insertion depth. (not too shallow or too deep)
Step 3:
Fix the mounting bracket on the wall using bolts & flat washers.
Step 4:
Put HYD-ES inverter on the mounting bracket.
Step 5:
Connect HYD-ES inverter to PE using the grounding hole on the heat sink.
Step 6:
OPTIONAL: you can lock HYD-ES inverter to the mounting bracket.
Step 5
Step 6