LEVEL 1-9
Zapi reserved.
-
LEVEL 10:
Enables the NO LOAD CURRENT test (see 12.4.2.10). Roll
from level 10 to level 15 and save the new setting to exit this
testing condition.
-
LEVEL 11:
Disables the alarms FB SENS LOCKED, MOTOR LOCKED
and POSITION ERROR (the latest only for FB ENC &
Toggle Switches configuration) till a new DEBUG OUTPUT
hand setting.
-
LEVEL 12:
The SET POINT POT of the Tester menu is connected at the
high resolution AD input (it is in the range 0 to 5Vdc when
the command potentiometer (CPOC1) is close to ZERO SP
POT).
-
LEVEL 13:
Reading SET POINT POT in the tester menu is connected to
the 2nd wiper of the twin (command) pot (CPOC2 on
CNA#8).
-
LEVEL 14:
Disables the alarms FB POT LOCKED, MOTOR LOCKED
and POSITION ERROR (the latest only for FB ENC &
TOGGLE SWs configuration). It switches automatically to the
default Level 15 recycling the key.
-
LEVEL 15:
Default value (no special functions activated).