
AEMZP0BA - EPS-AC0 - User Manual
Page - 75/95
12.4.5 Zapi menu “HARDWARE SETTINGS” functions list
To enter this Zapi hidden menu a special procedure is required. Ask this procedure
directly to a Zapi technician.
1) MAXIMUM
CURRENT
MAXIMUM CURENT sets the limit for the current in the controller.
2) CAN
BUS
ABSENT or PRESENT. This setting specifies whether the eps-ac0 is CAN Bus
connected or not. When CAN BUS is ABSENT, the CAN BUS KO alarm is
inhibited together with any starting sequence used to synchronize via CAN Bus
the eps-ac0 with the other controllers.
3) SET HI RESOL AD
When it is set to Level 1, enables an analog to digital conversion with high
resolution applied to the command pot CPOC1. Level 0 means the high
resolution AD conversion is inhibited. Level 2 is not used.
Содержание EPS-AC0
Страница 23: ...AEMZP0BA EPS AC0 User Manual Page 23 95 6 2 EPS AC0 Stepper Motor diagram Figure 6 2...
Страница 24: ...Page 24 95 AEMZP0BA EPS AC0 User Manual 6 3 EPS AC0 Twin pot diagram Figure 6 3...
Страница 54: ...Page 54 95 AEMZP0BA EPS AC0 User Manual 12 3 1 Stepper motor with Encoder and Feedback pot Figure 12 2...
Страница 55: ...AEMZP0BA EPS AC0 User Manual Page 55 95 12 3 2 RTC with Encoder and Feedback pot Figure 12 3...
Страница 56: ...Page 56 95 AEMZP0BA EPS AC0 User Manual 12 3 3 Stepper motor with Encoder and Toggle switch es Figure 12 4...