15-16
IM 760401-01E
15.5 Replacing the Fuse
WARNING
• The fuse used must be of the specified rating (current, voltage, type) in order to
prevent a fire hazard.
• Make sure to turn OFF the power switch and to unplug the power cord from its
source before replacing the fuse.
• Never short-circuit the fuse holder.
Fuse Ratings
The fuse used in the WT230 has the following specifications.
100V/200V Common
Maximum rated voltage: 250 V
Maximum rate curren: 1 A
Type: Time-lag
Approved standard: UL/VDE
Parts number: A1347EF
Replacing Procedure
Replace the fuse as follows.
1
Turn the power switch OFF.
2
Unplug the power cord from the power connector.
3
Place the tip of a flat-blade screwdriver in to the slot of the fuse holder, and
move the screwdriver in the direction of the arrow to remove the fuse holder.
4
Remove the blown fuse.
5
Insert a new fuse into the holder, then install the holder in place.
Fuse holder
Spare fuse
Fuse