5-3
IM 760401-01E
Displaying Measurement Results and Computation Results
5
5.2
Displaying Apparent Power, Reactive Power
and Power Factor
Keys
CHECK RANGE
MODE
UPDATE
SCALING
AVG
LINE
FREQ
STORE
RECALL
HARMONICS KEY LOCK
FILTER
A
B
C
VOLTAGE
VOLTAGE
VOLTAGE
AUTO
MODE
CURRENT
AUTO
RANGE
MAX HOLD
TRIG
CAL
INTEGRATOR
INTEG SET
SHIFT
KEY LOCK
1P 3W
3P 3W
3P 4W
3V 3A
OUTPUT
HARMONICS
MEMORY
REMOTE
MEAN
CURRENT
RMS
DC
FUNCTION
ELEMENT
MAX HOLD
HOLD
ENTER
RESET
WIRING
START
STOP
LOCAL
SETUP
1
m
V
k
A
V
TIME
ar
deg
h
h
VA
M W
m
V
PF
k
A
M W
m
V
Hz
k
A
M W
2
3
FUNCTION
ELEMENT
1
2
3
FUNCTION
ELEMENT
1
2
3
%
The explanation given in this section uses WT230 as an example. For the differences between
the WT210 and the WT230, see section 2.2, “Operation Keys and Functions/Element Display.”
Procedure
1. Selecting the Display Function
Select either VA (apparant power), var (reactive power), or PF (power factor) by
pressing the FUNCTION key of display A or B.
Display
A
B
FUNCTION
V
A
W
VA
var
TIME
V
A
W
PF
deg
FUNCTION
FUNCTION
FUNCTION
FUNCTION
FUNCTION
FUNCTION
FUNCTION
FUNCTION
FUNCTION
FUNCTION
You can reverse the order by first pressing the SHIFT key followed by the FUNCTION key.
2. Selecting the Input Element
Select the input element by pressing the ELEMENT key of display A or B. The
operation is the same as the one described on page 5-1.
Explanation
Maximum Reading, Unit, and Unit Prefix
• Maximum reading of apparent and reactive power: 99999 (when the number of
displayed digits is 5)
• Display range of power factor: –1.0000 to 1.0000 (when the num of displayed digits is 5)
(If the computed result lies between 1.0001 and 2.0000, 1.0000 is displayed. If it is
2.0001 or more, PFErr is displayed. If it is between –1.0001 and –2.0000, –1.0000
is displayed. If it is –2.0001 or below, PFErr is displayed.)
• Units: VA (apparent power), var (reactive power), power factor (no unit)
• Prefix: m, k, M,
Selecting the Display Function
The following selections are available.
• VA: apparent power will be displayed
• var: reactive power will be displayed
• PF: power factor will be displayed
Selecting the Input Element
• 1/2/3: Displays the measurement values of element 1/2/3
•
Σ
: Refer to page 5-2.
Note
•
Changing the measurement mode might result in different computed results, even when the
input signal is the same. For more details on the measurement mode, refer to page 4-1.
•
When either the voltage or current drops below 0.5% (less than or equal to 1% if the crest
factor is set to 6) of the measurement range, PFErr will be displayed.
Содержание WT210
Страница 1: ...Digital Power Meter IM 760401 01E 3rd Edition ...
Страница 208: ...13 18 IM 760401 01E 13 3 Sample Program Image ...
Страница 214: ...13 24 IM 760401 01E 13 5 Sample Program Output of Normal Measurement Data ...
Страница 266: ...14 50 IM 760401 01E 14 6 Sample Program Image ...
Страница 272: ...14 56 IM 760401 01E 14 8 Sample Program Output of Normal Measurement Data ...