6
-4
When switching between the master and auxiliary speeds, set H3-05 (Multi-function analog input terminal
A3) to 2 (auxiliary frequency reference, 2nd step analog) and set on of the multi-function input terminals to
multi-step speed reference 1.
When inputting a current to terminal A2 for the master speed frequency reference, set H3-08 (Multi-function
analog input terminal A2 signal level selection) to 2 (current input), and set H3-09 (Multi-function analog
input terminal A2 function selection) to 0 (add to terminal A1).
Fig 6.4 Switching between Master and Auxiliary Frequencies
Setting Frequency Reference Using Pulse Train Signals
When b1-01 is set to 4, the pulse train input to control circuit terminal RP is used as the frequency reference.
Set H6-01 (Pulse Train Input Function Selection) to 0 (frequency reference), and then set the 100% reference
pulse frequency to H6-02 (Pulse Train Input Scaling).
Fig 6.5 Frequency Reference Using Pulse Train Input
In
v
erter
A1
A2
A3
Master speed
fre
qu
ency reference
(
v
oltage inp
u
t)
Master speed
fre
qu
ency reference
(c
u
rrent inp
u
t)
A
u
xiliary speed
fre
qu
ency reference 1
AC Analog common
2 k
Ω
+
V
2 k
Ω
S5 M
u
lti-step speed
reference 1
4 to 20 mA
Po
w
er s
u
pply: 15
V
,
20 mA
Pulse Input Specifications
Low level voltage
0.0 to 0.8 V
High level voltage
3.5 to 13.2 V
Heavy duty
30% to 70%
Pulse frequency
0 to 32 kHz
Inverter
RP(Pulse train input termi-
nal)
AC (Analog common)
32 kHz max.
3.5 to 13.2 V
Pulse input
TOE-S616-60.1.book 4 ページ 2017年8月4日 金曜日 午後3時41分