User Constant Tables
5-
91
* 1. The settings will be 0.05 (Flux vector)/1.00 (open-loop vector) for Inverters of 45kW or larger.
* 2. The settings shown are for 200 V Class Inverters. The values will double for 400 V Class Inverters.
* 3. Settings vary as shown in the following tables depending on the Inverter capacity and E1-03.
* 4. The setting range for open-loop vector 2 control is 0 to 66.0 (0 to 132.0 for
PRG 103
).
For the 400 V Class Inverters, there are limitations on the maximum output frequency depending on the setting for the carrier frequency and capacity.
The maximum output frequency for 400 V, 90 to 110 kW is 250 Hz. The maximum output frequency for 400 V, 132 to 300 kW is 166 Hz.
* 5. 1000 ms for Inverters of 200 V Class 30 to 110 kW and 400 V Class 55 to 300 kW.
* 6. The setting ranges depend on the control method and capacity of the Inverter. (The values for a 200 V Class Inverter for 0.4 kW are given.)
* 7. The factory setting depends on the Inverter capacity. (The value for a 200 V Class Inverter of 0.4 kW is given.)
* 8. Applicable for G7-Series Inverters with software versions PRG 1040 and later.
200 V and 400 V Class Inverters of 0.4 to 1.5 kW
* The setting shown are for 200 V Class Inverters. The values will double for 400 V Class Inverters.
E1-07
E3-05
Mid. output frequency (FB)
0.0 to 400.0
0.1 Hz
3.0
*3
3.0
*3
3.0
0.0
0.0
Mid Frequency A
E1-08
E3-06
Mid. output frequency voltage (VC)
*2
0.0 to 255.0
(0.0 to 510.0)
0.1 V
15.0
*3
15.0
*3
11.0
0.0
0.0
Mid Voltage A
E1-09
E3-07
Min. output frequency (FMIN)
0.0 to 400.0
0.1 Hz
1.5
*3
1.5
*3
0.5
0.0
0.3
Min Frequency
E1-10
E3-08
Min. output frequency voltage (VMIN)
*2
0.0 to 255.0
(0.0 to 510.0)
0.1 V
9.0
*3
9.0
*3
2.0
0.0
1.0
Min Voltage
F1-09
Overspeed detection delay time
0.0 to 2.0
0.1 s
–
1.0
–
0.0
0.0
PG Overspd Time
N5-01
Feedforward control selection
0, 1
1
–
–
–
0
1
Feedfoward Sel
Con-
stant
Num-
ber
Unit
Factory Setting
Open
Loop
Vector
Con-
trol
1
Open
Loop
Vector
Con-
trol
2
Flux
Vector
Con-
trol
E1-03
-
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
E1-04 Hz
50.0
60.0
60.0
72.0
50.0
50.0
60.0
60.0
50.0
50.0
60.0
60.0
90.0
120.0 180.0
60.0
60.0
60.0
60.0
E1-05
*
V
200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0 200.0
E1-06 Hz
50.0
60.0
50.0
60.0
50.0
50.0
60.0
60.0
50.0
50.0
60.0
60.0
60.0
60.0
60.0
60.0
60.0
60.0
0.0
E1-07 Hz
2.5
3.0
3.0
3.0
25.0
25.0
30.0
30.0
2.5
2.5
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
0.0
E1-08
*
V
15.0
15.0
15.0
15.0
35.0
50.0
35.0
50.0
19.0
24.0
19.0
24.0
15.0
15.0
15.0
15.0
11.0
13.3
0.0
E1-09 Hz
1.3
1.5
1.5
1.5
1.3
1.3
1.5
1.5
1.3
1.3
1.5
1.5
1.5
1.5
1.5
1.5
0.5
0.3
0.0
E1-10
*
V
9.0
9.0
9.0
9.0
8.0
9.0
8.0
9.0
11.0
13.0
11.0
15.0
9.0
9.0
9.0
9.0
2.0
1.3
0.0
Con-
stant
Number
Name
Setting Range
Unit
Factory Setting
Display
V/f
Control
V/f with
PG
Open-
loop
Vector
1
Flux
Vector
Open
Loop
Vector
2
TOE-S616-60.1.book 91 ページ 2017年8月4日 金曜日 午後3時41分