3.7 EMC Installation Conditions
3-10
•
Single-Phase, 200 VAC
Symbol
Cable Name
Specification
I/O Signal Cable
Shielded cable
Safety Function Device Cable
Shielded cable
Servomotor Main Circuit Cable
Shielded cable
Encoder Cable
Shielded cable
Main Circuit Power Cable
Shielded cable
MECHATROLINK-III Communications Cable Shielded cable
CN1
CN2
L1C and L2C
CN6A and CN6B
L1 and L2
U, V, and W
Noi
s
e
filter
S
urge
ab
s
orber
Clamp
Brake
S
ervomotor
Encoder
Brake power
s
upply
S
ERVOPACK
S
afety
function device
I/O
controller
PE
PE
S
hield box
Power
s
upply:
S
ingle-pha
s
e, 200 VAC
Clamp
Clamp
Clamp
Clamp
Clamp
Clamp
MECHATROLINK-III
Controller
Clamp
CN8