
4.4 Wiring Servomotors
4.4.4 Wiring the SERVOPACK to the Holding Brake
4
W
iring and Connecting
S
ER
VOP
ACK
s
4-33
4.4.4
Wiring the SERVOPACK to the Holding Brake
*
Install the surge absorber near the brake terminals on the Servomotor.
•
If you use a Rotary Servomotor, select a Surge Absorber according to the brake current and
brake power supply. Refer to the following manual for details.
Σ
-7-Series Peripheral Device Selection Manual (Manual No.: SIEP S800001 32)
•
After the Surge Absorber is connected, check the brake operation delay time in your applica-
tion. The Surge Absorber may affect the brake operation delay time.
Configure the relay circuit to activate the holding brake for an emergency stop.
•
You can change the output signal allocation of the /BK signal. Refer to the following section for
details.
Allocating the /BK (Brake) Signal
•
If you use a 24-V brake, install a separate power supply for the 24-VDC power supply from
other power supplies, such as the one for the I/O signals of the CN1 connector. If the power
supply is shared, the I/O signals may malfunction.
Important
Relay Circuit Example
0 V
Emergency
s
top
5 VDC to
3
0 VDC
S
ERVOPACK
Photocoupler
S
ervomotor with
Holding Brake
S
ERVOPACK
S
urge Ab
s
orber
Power
s
upply
BK-RY: Brake control relay
1D: Flywheel diode
M
BK
ENC
U
V
W
CN2
AC
DC
BK-RY
BK-RY
+24 V
L1
L2
L
3
L1C
L2C
(/BK+)
(/BK-)
CN1
Brake power
s
upply
DC
s
ide
1D
0 V
*