6.13 Forcing the Motor to Stop
6.13.3 Resetting Method for Forced Stops
6
Application Function
s
6-61
6.13.3
Resetting Method for Forced Stops
This section describes the reset methods that can be used after stopping operation for an
FSTP (Forced Stop Input) signal.
If the FSTP (Forced Stop Input) signal is OFF and the SV_ON (Servo ON) command is sent, the
forced stop state will be maintained even after the FSTP signal is turned ON.
Send the SV_OFF (Servo OFF) command to place the SERVOPACK in the base block (BB)
state and then send the SV_ON (Servo ON) command.
Forced
s
top
s
tate:
F
S
TP i
s
di
s
played.
BB
s
tate
Operating
s
tate
OFF
(forced
s
top reque
s
t)
ON (normal operation)
F
S
TP
s
ignal
ON (normal operation)
Operating
s
tate
S
V_ON
command
S
V_ON
command
S
V_OFF
command
S
ERVOPACK
s
tate
MECHATROLINK-III
command