3.7 EMC Installation Conditions
3-9
3
S
ER
VOP
ACK In
s
tallation
3.7
EMC Installation Conditions
This section gives the installation conditions that were used for EMC certification testing.
The EMC installation conditions that are given here are the conditions that were used to pass
testing criteria at Yaskawa. The EMC level may change under other conditions, such as the
actual installation structure and wiring conditions. These Yaskawa products are designed to be
built into equipment. Therefore, you must implement EMC measures and confirm compliance
for the final equipment.
The applicable standards are EN 55011 group 1 class A, EN 61000-6-2, EN 61000-6-4, and
EN 61800-3 (category C2, second environment).
•
Three-Phase, 200 VAC
Symbol
Cable Name
Specification
I/O Signal Cable
Shielded cable
Safety Function Device Cable
Shielded cable
Servomotor Main Circuit Cable
Shielded cable
Encoder Cable
Shielded cable
Main Circuit Power Cable
Shielded cable
MECHATROLINK-III Communications Cable Shielded cable
CN1
CN2
L1C and L2C
CN6A and CN6B
L1, L2, and L
3