8.5 Estimating the Moment of Inertia
8.5.4 Operating Procedure
8-22
12.
Repeat steps 9 to 11 until the
Next
Button is enabled.
Measurements are performed from 2 to 7 times and then verified. The number of measurements is
displayed in upper left corner of the dialog box. A progress bar at the bottom of the dialog box will
show the progress of the transfer each time.
13.
When the measurements have been completed, click the
Servo On
Button to turn OFF
the servo.
14.
Click the
Next
Button.
The Write Results Dialog Box will be displayed.
15.
Click the
Writing Results
Button.
Identified Moment of Inertia Ratio
Box
The moment of inertia ratio that was found with operation and measurements is dis-
played here.
Writing Results
Button
If you click this button, Pn103 (Moment of Inertia Ratio) in the SERVOPACK is set to the
value that is displayed for the identified moment of inertia ratio.
Pn103: Moment of Inertia Ratio
Box
The value that is set for the parameter is displayed here.
After you click the
Writing Results
Button, the value that was found with operation and
measurements will be displayed as the new setting.
Back
Button
This button is disabled.
Cancel
Button
This button will return you to the Tuning Dialog Box.
16.
Confirm that the
Identified Moment of Inertia Ratio
Box and the
Pn103: Moment of
Inertia Ratio
Box show the same value and then click the
Finish
Button.
17.
Click the
OK
Button.
If you click the
Next
Button before you turn OFF the servo, the following Dialog Box will
be displayed. Click the
OK
Button to turn OFF the servo.
Information