8.5 Estimating the Moment of Inertia
8.5.4 Operating Procedure
8-20
Confirm
Button
Click this button to display the Reference Confirmation Dialog Box.
Detailed Setting
Area
You can change the settings by moving the bars or directly inputting the settings to cre-
ate the required reference pattern.
Next
Button
Click this button to display the Reference Transmission Dialog Box.
Cancel
Button
Click this button to return to the Tuning Dialog Box.
6.
Click the
Next
Button.
The Reference Transmission Dialog Box will be displayed.
7.
Click the
Start
Button.
Start
Button
The reference conditions will be transferred to the SERVOPACK. A progress bar will show
the progress of the transfer.
Cancel
Button
The
Cancel
Button is enabled only while data is being transferred to the SERVOPACK.
You cannot use it after the transfer has been completed.
CAUTION
The travel distance is the distance for one operation in the forward or reverse direction.
During multiple operations, the operation starting position may move in one direction or the
other. Confirm the possible operating range for each measurement or operation.
Depending on the parameter settings and the moment of inertia of the machine, overshoot-
ing and undershooting may occur and may cause the maximum speed setting to be
exceeded temporarily. Allow sufficient leeway in the settings.
When Measurement Is Not Correct
Estimating the moment of inertia ratio cannot be performed correctly if the torque limit is
activated. Adjust the limits or reduce the acceleration rate in the reference selection so
that the torque limit is not activated.
Information