13.1 List of Servo Parameters
13.1.2 List of Servo Parameters
13-6
Pn007
2
Application Function
Selections 7
0000h to
105Fh
–
0000h
All
Immedi-
ately
Setup
Pn008
2
Application Function
Selections 8
0000h to
7121h
–
4000h
Rotary
After
restart
Setup
–
Continued on next page.
Continued from previous page.
Parameter
No.
Size
Name
Setting
Range
Setting
Unit
Default
Setting
Applicable
Motors
When
Enabled
Classi-
fication
Refer-
ence
n.
XX
Analog Monitor 2 Signal Selection
00
Motor speed (1 V/1,000 min
-1
)
Motor speed (1 V/1,000 mm/s)
01
Speed reference (1 V/1,000 min
-1
)
Speed reference (1 V/1,000 mm/s)
02
Torque reference (1 V/100% rated torque)
Force reference (1 V/100% rated force)
03
Position deviation (0.05 V/reference unit)
04
Position amplifier deviation (after electronic gear) (0.05 V/encoder pulse unit)
Position amplifier deviation (after electronic gear) (0.05 V/linear encoder
pulse unit)
05
Position reference speed (1 V/1,000 min
-1
)
Position reference speed (1 V/1,000 mm/s)
06
Reserved setting (Do not use.)
07
Load-motor position deviation (0.01 V/reference unit)
08
Positioning completion (positioning completed: 5 V, positioning not com-
pleted: 0 V)
09
Speed feedforward (1 V/1,000 min
-1
)
Speed feedforward (1 V/1,000 mm/s)
0A
Torque feedforward (1 V/100% rated torque)
Force feedforward (1 V/100% rated force)
0B
Active gain (1st gain: 1 V, 2nd gain: 2 V)
0C
Completion of position reference distribution (completed: 5 V, not com-
pleted: 0 V)
0D
External encoder speed (1 V/1,000 min
-1
: value at the motor shaft)
0E
Reserved setting (Do not use.)
0F
Reserved setting (Do not use.)
10
Main circuit DC voltage
11 to 5F
Reserved settings (Do not use.)
n.
X
Reserved parameter (Do not change.)
n.X
Reserved parameter (Do not change.)
n.
X
Low Battery Voltage Alarm/Warning Selection
Reference
0
Output alarm (A.830) for low battery voltage.
1
Output warning (A.930) for low battery voltage.
n.
X
Function Selection for Undervoltage
Reference
0
Do not detect undervoltage.
1
Detect undervoltage warning and limit torque at host controller.
2
Detect undervoltage warning and limit torque with Pn424 and
Pn425 (i.e., only in SERVOPACK).
n.
X
Warning Detection Selection
Reference
0
Detect warnings.
1
Do not detect warnings except for A.971.
n.X
Reserved parameter (Do not change.)