ELEC
MAIN SWITCH
1. Disconnect:
• Main switch coupler
2. Connect:
• Pocket tester
3. Inspect:
• Main switch continuity
Faulty
→
Replace.
LOAD RELAY
1. Inspect:
• Load relay
Inspection steps:
• Disconnect the load relay from the coupler.
• Connect the pocket tester (
Ω
×
1) and battery
(12 V) to the load relay terminals as shown.
Positive battery terminal
→
Brown
Negative battery terminal
→
Brown/Blue
Positive tester probe
→
Red
Negative tester probe
→
White
• If load relay does not have continuity
between the red and blue terminals, replace
it.
Switch position
Continuity
OFF
Yes
ON
No
Switch
position
Color code
R
Br
R/W
Br/W
OFF
ON
START
Continuity
IGNITION SYSTEM