8 expansion devices
※
1: When no signal input, the channel’s data is 4095;
※
2: According to the actual requirements, connect with the thermo-resistors;
0V
24V
TC1+
TCO-
TC1-
TC2-
TC3-
TC4-
TC5-
TC5+
TC4+
TC3+
TC2+_
TC0+
Y1
.
Y5
Y3
COM2
COM1
COM0
Y0
Y2
Y4
CH
NAME SIGNAL
CH
NAME SIGNAL
CH0
TC0+
CH0 temperature input
+
CH1 TC1+
CH1 temperature input
+
TC0-
CH0 temperature input
-
TC1-
CH1 temperature input
-
CH2 TC2+
CH2 temperature input
+
CH3 TC3+
CH3 temperature input
+
TC2-
CH2 temperature input
-
TC3-
CH3 temperature input
-
CH4 TC4+
CH4 temperature input
+
CH5 TC5+
CH5 temperature input
+
TC4-
CH4 temperature input
-
TC5-
CH5 temperature input
-
Y0~Y5
Output Channel Y0
~
Y5
Analogue Output: in the form of digital type, the range is 0~4095
Digital Output: in the form of occupy ratio, Y output in the activate time
-
24V
+24V power supply
0V
COM of power supply
Items
Specifications
Analogue Input Signal
K
、
S
、
E
、
N
、
J
、
T
、
R type thermocouples
Temperature testing range
0
℃
~
1000
℃
Digital Output range
0
~
4095, without sign 12 bits, decimal
Control precision
0.1
℃
Distinguish Ratio
0.1
℃
Integral Precision
0.1
℃
Convert Speed
20ms/CH
Power Supply
DC24V±10%, 50mA
Specification
2
Terminal Arrangement
3
Содержание XC Series
Страница 1: ...WUXI XINJE ELECTRIC CO LTD XC series PLC hardware User manual Data No PC01 20110106 3 3 ...
Страница 4: ......
Страница 41: ...3 System Structure Analog Output QD QD1000 QD1031 16 channels Module s Value D D8320 D8329 ...
Страница 43: ...3 System Structure Please install the products according to chapter 2 1 1 3 Installation Environment ...
Страница 49: ...5 Input Specifications and Wiring Methods 5 2 DC Input Signal AC Power Supply Type DC Input Signal 1 ...
Страница 51: ...5 Input Specifications and Wiring Methods ...
Страница 125: ...Appendix special soft device list 1 If you change special FLASH memory it will take into effect after restart the PLC ...